コンテンツへスキップ
Merck

71015BC

Millipore

GDS MPX Top 7 STEC

BioControl, Molecular based PCR test for the detection of E. coli O157:H7 and the "Top Six" non-O157 Shiga Toxigenic E. coli (STEC) in food

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41106302

認証

AOAC® (PTM)

品質水準

シェルフライフ

6‑12 mo.

包装

pkg of 100 tests

メーカー/製品名

Assurance GDS®
BioControl Systems 71015-100
BioControl Systems 71015-576

テクニック

PCR: suitable

アプリケーション

food and beverages
pathogen testing

適合性

for use with GDS Rotor-Gene
enterovirulent E. coli (EEC) (shiga toxigenic)

保管温度

2-8°C

詳細

Assurance® GDS is an advanced genetic detection system for food pathogens. The MPX Top 7 STEC is an automated nucleic acid amplification system for the detection of E. coli O157:H7 and the "Top Six" non-O157 Shiga Toxigenic E. coli (STEC). The Top Six non-O157 STEC are defined as E. coli belonging to serogroups O103, O111, O121, O145, O26, or O45 that possess both the eae gene and at least one of the shiga toxin genes (stx1 or stx2). Assurance® GDS MPX Top 7 STEC utilizes a proprietary PickPen® IMS-based sample preparation procedure to quickly and effectively capture organisms belonging to the 7 specific Top STEC O serogroups prior to genetic analysis for the associated pathogenicity genes.

アプリケーション

Assurance® GDS MPX Top 7 STEC is suitable for the detection of E. coli O157:H7 and the “Top Six” non-O157 Shiga Toxigenic E. coli (STEC) in foods, ingredients, and environmental samples.

特徴および利点

  • Following sample preparation with IMS against the Top 7 O groups, samples are analyzed with a single multiplex assay for the presence of (eae), stx1, and stx2
  • Assurance® GDS MPX Top 7 STEC assay includes a separate target and differentiated result for E. coli O157:H7
  • Single-step 10-18 h enrichment in mEHEC®, enrichment media common to all BioControl methods for E.coli O157:H7, Shiga Toxin genes, and Top STEC

構成

  • MPX Top STEC Amplification Tubes
  • Top 7 STEC Concentration ReagentResuspension Buffer TqTop STEC Wash Solution

適合性

BioControl GDS

試験法

PCR, Immunomagnetic Separation (IMS)

法的情報

AOAC is a registered trademark of AOAC International
Assurance is a registered trademark of Merck KGaA, Darmstadt, Germany
Assurance GDS is a registered trademark of BioControl Systems, Inc.
PICKPEN is a registered trademark of Merck KGaA, Darmstadt, Germany
mEHEC is a registered trademark of Merck KGaA, Darmstadt, Germany

ピクトグラム

Corrosion

シグナルワード

Warning

危険有害性情報

注意書き

危険有害性の分類

Met. Corr. 1

保管分類コード

8A - Combustible, corrosive hazardous materials

WGK

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

毒物及び劇物取締法

キットコンポーネントの情報を参照してください

PRTR

キットコンポーネントの情報を参照してください

消防法

キットコンポーネントの情報を参照してください

労働安全衛生法名称等を表示すべき危険物及び有害物

キットコンポーネントの情報を参照してください

労働安全衛生法名称等を通知すべき危険物及び有害物

キットコンポーネントの情報を参照してください

カルタヘナ法

キットコンポーネントの情報を参照してください

Jan Code

キットコンポーネントの情報を参照してください


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)