おすすめの製品
product name
BioTracker™ Red pH-Independent Autophagy Live Cell Probe,
由来生物
human
品質水準
包装
vial of 5 nmol
メーカー/製品名
Millipore
テクニック
cell culture | stem cell: suitable
flow cytometry: suitable
輸送温度
2-8°C
保管温度
2-8°C
詳細
The small fluorescent molecule SCT277 is used to detect autophagosomes and autolysosomes. The presumed mechanism is that the dye is incorporated into the autophagosome during double-membrane formation via structural features, and then emits fluorescence under hydrophobic conditions. The probe emits in the far red range.SPECTRAL CHARACTERISTICS: Excitation λ: 530 nmEmission λ: 720 nm
特徴および利点
Fluorescence microscopyFlow cytometry
ターゲットの説明
BioTracker Red pH-Independent Autophagy Live Cell Probe detects autophagosomes and autolysosomes. The presumptive mechanism involves incorporation of the probe via structural features into the autophagosome during double-membrane formation. Upon incorporation, the probe emits fluorescence under hydrophobic conditions. The utility of the probe is conferred by molecular properties that include cell permeability, does not require transfection, and enables live cell detection with fluorescence microscopy or other fluorescence capture instruments.
保管および安定性
Store at -20 °C, protected from light.
その他情報
SCT277 detects autophagosomes and autolysosomes by the likely mechanism of incorporation into the autophagosome during double membrane formation, and emits red fluorescence under hydrophobic conditions. SCT277 is cell permeable, does not require transfection, and enables live cell imaging with fluorescence microscopy and quantitative assay by flow cytometry.Add 50 uL DMSO to tube of SCT277 (5 nmol) and pipet to dissolve to make a 0.1 mM stock solution. Dilute with culture medium to 0.1 - 0.5 uM to make working solution.
法的情報
BioTracker is a trademark of Merck KGaA, Darmstadt, Germany
免責事項
Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.
保管分類コード
11 - Combustible Solids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
SCT277:
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)