コンテンツへスキップ
Merck
すべての画像(1)

Key Documents

安全性情報

AAWP09050

Millipore

MF-Millipore Membrane Filter, 0.8 µm pore size

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
40161507
eCl@ss:
32031602

物質

plain white mixed cellulose esters (MCE) filter

特徴

hydrophilic

メーカー/製品名

MF-Millipore

パラメーター

max. temp. at 75 °C
16 L/min-cm2 air flow rate
190 mL/min-cm2 water flow rate

filter diam. × thickness

90 mm × 180 μm

重量分析抽出物

4%

屈折率

n/D 1.51

ポアサイズ

0.8 μm pore size

泡立ち点

≥1.10 bar, air with water

詳細

AAWP
Biologically inert mixtures of cellulose acetate and cellulose nitrate have made MF-Millipore membrane filters one of the most widely used membranes in analytical and research applications.

MF-Millipore filters without Triton surfactant contain minimum amounts of wetting agent and have a lower water extractable content than standard MF-Millipore filters.

Features & Benefits:
- Versatile filter for biological and environmental monitoring applications
- Available in a range of pore sizes, colored black or white, with or without a gridded surface
- Compatible with ethylene oxide, gamma irradiation, and autoclave sterilization methods
Screen filter

アプリケーション

  • Air monitoring
  • Particle monitoring
  • Particle removal
  • Bioassays
  • Microplastics

法的情報

MF-Millipore is a trademark of Merck KGaA, Darmstadt, Germany
Triton is a trademark of The Dow Chemical Company or an affiliated company of Dow

ピクトグラム

Flame

シグナルワード

Danger

危険有害性情報

危険有害性の分類

Flam. Sol. 1

保管分類コード

4.1B - Flammable solid hazardous materials

WGK

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Jan Code

AAWP09050:


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.