おすすめの製品
product name
Chromolith® CapRod RP-18 endcapped Capillary Columns, L × I.D. 150 mm x 0.2 mm capillary column
物質
PEEK column
品質水準
認証
suitable for USP L1
製品種目
Chromolith®
特徴
endcapped
包装
1 ea of
標識化の程度
18% Carbon loading
パラメーター
218 bar pressure
テクニック
HPLC: suitable
LC/MS: suitable (Capillary LC)
mass spectrometry (MS): suitable (High)
カラムL × 内径
15 cm × 0.2 mm
マトリックス
monolithic silica
マトリックス活性基
C18 bonding phase
ポアサイズ
13 nm mesoporosity
2 μm macroporosity
operating pH range
2-7.5
分離法
reversed phase
保管温度
no temp limit
類似した製品をお探しですか? 訪問 製品比較ガイド
関連するカテゴリー
詳細
A Chromolith® CapRod capillary column combines the speed of monolithic silica technology with the sensitivity of nano-LC. This enables superior productivity for high throughput, highly sensitive proteomics-LC applications.
Compared to particulate capillary columns, Chromolith® CapRod capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument.
Chromolith® CapRod columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).
Why choose Chromolith® CapRod capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces
Chromolith® CapRod RP-18 endcapped can be operated at significantly higher flow rates without loss of performance. The typical flow rate for this 150-0.2 capillary column ranges from 5 μL/min to 20 μL/min.
Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns
Compared to particulate capillary columns, Chromolith® CapRod capillaries demonstrate better performance with optimal resolution (narrow peak widths), increased productivity (higher sample throughput), and extended column lifetime. Furthermore, column length is less limited than with any other type of column. The capillaries can even be slightly bent to fit any LC configuration or instrument.
Chromolith® CapRod columns are designed to work with various nano or capillary-LC systems. This provides the highest efficiency and performance when coupled to mass spectrometers, both on-line (ESI, nanospray) and off-line (MALDI).
Why choose Chromolith® CapRod capillary columns?
—Higher flow rates than particle-packed capillary columns
—Columns at low pressure
—Long column lifetime
—Robust and easy handling
—Flow rates from 0.1–200 μL/min ensure ideal compatibility with LC/MS systems, with both ESI and APCI interfaces
Chromolith® CapRod RP-18 endcapped can be operated at significantly higher flow rates without loss of performance. The typical flow rate for this 150-0.2 capillary column ranges from 5 μL/min to 20 μL/min.
Learn more:
Brochure: Race through your Separations on Any System. Chromolith® Monolithic Silica HPLC Columns
法的情報
Chromolith is a registered trademark of Merck KGaA, Darmstadt, Germany
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)