コンテンツへスキップ
Merck

1.09139

Supelco

水酸化ナトリウム 溶液

c(NaOH) = 0.25 mol/l (0.25 N), ready-to-use volumetric solution for titration, Titriplex®

ログイン組織・契約価格を表示する


About This Item

化学式:
NaOH
CAS番号:
分子量:
40.00
MDL番号:
UNSPSCコード:
12352305
NACRES:
NA.21

product name

水酸化ナトリウム 溶液, c(NaOH) = 0.25 mol/l (0.25 N), Titripur®

蒸気圧

3 mmHg ( 37 °C)

品質水準

製品種目

Titripur®

形状

liquid

品質

Analyzed in our ISO 17025 accredited QC lab

反応適合性

reaction type: Acid-base reactions

包装

Titripac® of

濃度

0.25 M

テクニック

titration: suitable

pH

13.5 (20 °C in H2O)

密度

1.01 g/cm3 at 20 °C

保管温度

15-25°C

SMILES記法

[OH-].[Na+]

InChI

1S/Na.H2O/h;1H2/q+1;/p-1

InChI Key

HEMHJVSKTPXQMS-UHFFFAOYSA-M

類似した製品をお探しですか? 訪問 製品比較ガイド

アプリケーション


  • Adsorption Studies: Sodium hydroxide solution is used in treating polymer adsorbents to enhance their adsorption properties. A recent study investigated the effect of treating a PVC/Aliquat-336 polymer adsorbent with sodium hydroxide on chromium (VI) adsorption. The treatment improved the adsorption capacity of the polymer, making it more effective in removing heavy metals from aqueous solutions (Ouazine et al., International Journal of Environmental Analytical Chemistry, 2022).

  • Synthesis of Sodium Ethoxide: Sodium hydroxide solution is employed in the synthesis of sodium ethoxide, an important reagent in organic synthesis. Research has demonstrated that sodium ethoxide can be synthesized efficiently at ambient temperature using sodium hydroxide and ethanol-90. This method offers a straightforward and cost-effective approach for preparing this key chemical intermediate (Randriana et al., World Journal of Applied Chemistry, 2021).

  • Corrosion Inhibition: Sodium hydroxide solution is used in corrosion inhibition studies. Research has shown that an aqueous extract of Thespesia populnea plant leaves can effectively inhibit the corrosion of aluminum steel in sodium hydroxide solution. The study utilized electrochemical techniques to demonstrate the formation of a protective film on the steel surface, highlighting the potential of natural inhibitors in industrial applications (Brindha and Venkatraman, Research Journal of Chemistry and Environment, 2023).

特徴および利点

Accreditation:
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.

包装

SKU-pack size numbers ending with a "3" are SmartChemicals with an RFID tag on the label for seamless data transfer to the instrument, e.g. xxxxxx1003 or xxxxxxx 4003. More information on www.sigmaaldrich.com/SmartChemicals

Titripac® packaging - all SKU-pack size numbers ending "4000, 4003, 9010, 9013" - more information on www.sigmaaldrich.com/Titripac

アナリシスノート

Form liquid
Amount-of-substance concentration 0.24875 - 0.25125 mol/L
Measurement uncertainty ± 0.00075 mol/L
Traceability NIST SRM

The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.

Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.

法的情報

Titripac is a registered trademark of Merck KGaA, Darmstadt, Germany
Titripur is a registered trademark of Merck KGaA, Darmstadt, Germany

関連製品

製品番号
詳細
価格

ピクトグラム

Corrosion

シグナルワード

Warning

危険有害性情報

危険有害性の分類

Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2

保管分類コード

8B - Non-combustible, corrosive hazardous materials

WGK

nwg

引火点(°F)

Not applicable

引火点(℃)

Not applicable


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

資料

SmartChemicals enable wireless transfer of CoA data stored on an RFID tag on the consumable bottle to the titrator, reducing effort and chance for human error. Crucial data required for the application is transmitted safely, reliably and intelligently to the instrument.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.