Passa al contenuto
Merck
Tutte le immagini(1)

Key Documents

370037

Supelco

Poly(methyl methacrylate)

analytical standard, for GPC, average Mw 97,000 (Typical), average Mn 46,000 (Typical)

Sinonimo/i:

PMMA

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula condensata:
[CH2C(CH3)(CO2CH3)]n
Numero CAS:
Numero MDL:
Codice UNSPSC:
41116107
ID PubChem:
NACRES:
NA.24

Grado

analytical standard
for GPC

Livello qualitativo

Temp. autoaccensione

580 °F

PM

average Mn 46,000 (Typical)
average Mw 97,000 (Typical)

tecniche

gel permeation chromatography (GPC): suitable

Solubilità

H2O: insoluble

Densità

1.200 g/cm3

Formato

neat

InChI

1S/C5H9O2/c1-4(2)5(6)7-3/h1-3H3
PMAMJWJDBDSDHV-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Codice della classe di stoccaggio

11 - Combustible Solids

Classe di pericolosità dell'acqua (WGK)

nwg

Dispositivi di protezione individuale

Eyeshields, Gloves, type N95 (US)


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

Pleural infection 55 years after plombage for pulmonary tuberculosis.
Qian-kun Chen et al.
Asian cardiovascular & thoracic annals, 21(1), 100-100 (2013-02-23)
Gursukhman S Sidhu et al.
Journal of neurosurgery. Spine, 19(1), 61-70 (2013-05-07)
The authors endeavor to highlight the surgical management of severe neurological deficit resulting from cement leakage after percutaneous vertebroplasty and to systematically review the literature on the management of this complication. A patient presented after a vertebroplasty procedure for traumatic
S A Bini et al.
The bone & joint journal, 95-B(3), 367-370 (2013-03-02)
We evaluated the impact of pre-coating the tibial component with polymethylmethacrylate (PMMA) on implant survival in a cohort of 16 548 primary NexGen total knee replacements (TKRs) in 14 113 patients. In 13 835 TKRs a pre-coated tray was used
Kariem Mostafa Al Batouty et al.
The journal of adhesive dentistry, 15(2), 161-166 (2013-03-28)
To compare the push-out bond strength of a new glass fiber root canal filling material to that of Resilon/ Epiphany, EndoREZ, and gutta-percha/AH Plus root canal filling materials. Sixty roots were randomly divided into four groups (n = 15) according
Patrick M Honore et al.
ASAIO journal (American Society for Artificial Internal Organs : 1992), 59(2), 99-106 (2013-02-27)
In recent years, after all the attention has been focused on the dose for continuous renal replacement therapy (CRRT) in sepsis and systemic inflammation response syndrome (SIRS), the relatively negative results of all those studies did urge our expectations on

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.