跳转至内容
Merck

40390

Sigma-Aldrich

二甲基乙二肟

puriss. p.a., ACS reagent, for the detection of Ni, ≥99.0% (TLC)

别名:

2,3-丁二酮二肟, 丁二酮肟

登录查看公司和协议定价


About This Item

线性分子式:
CH3C(=NOH)C(=NOH)CH3
CAS号:
分子量:
116.12
Beilstein:
506731
EC號碼:
MDL號碼:
分類程式碼代碼:
12352100
PubChem物質ID:
NACRES:
NA.21

等級

ACS reagent
puriss. p.a.

品質等級

化驗

≥99.0% (TLC)

形狀

solid

品質

for the detection of Ni

技術

UV/Vis spectroscopy: suitable

雜質

≤0.02% insoluble matter in ethanol

燃燒殘留物

≤0.05% (as SO4)

mp

240-241 °C (lit.)

溶解度

water: soluble 0.1 g/10 mL, clear, colorless

正離子痕跡

Ca: ≤10 mg/kg
Cd: ≤5 mg/kg
Co: ≤5 mg/kg
Cr: ≤5 mg/kg
Cu: ≤5 mg/kg
Fe: ≤5 mg/kg
K: ≤50 mg/kg
Mg: ≤5 mg/kg
Mn: ≤5 mg/kg
Na: ≤50 mg/kg
Ni: ≤5 mg/kg
Pb: ≤5 mg/kg
Zn: ≤5 mg/kg

官能基

amine
oxime

SMILES 字串

CC(=N/O)\C(C)=N\O

InChI

1S/C4H8N2O2/c1-3(5-7)4(2)6-8/h7-8H,1-2H3/b5-3+,6-4+

InChI 密鑰

JGUQDUKBUKFFRO-GGWOSOGESA-N

正在寻找类似产品? 访问 产品对比指南

一般說明

二甲基乙二肟(DMG)是一种络合配体。 二甲基乙二肟可与带有诸如VO(IV)、Ni(II)、Zn(II)、Pd(II)、Cd(II)和Pb(II)等金属的N-乙酰基甘氨酸形成许多混合配体络合物。它是用于分光光度法测定Co(II)、Fe(II)、Ni(II)、Pd(II)和Re(VII)的有效试剂。

應用

二甲基乙二肟(DMG)被用作钴(II)和镍(II)金属的络合剂,可用于通过吸附溶出伏安法分析盐水中的痕量金属。 在一项研究中,DMG已被用于开发一种新型DMG,其包含改性溶胶-凝胶碳复合电极,从而用于重金属伏安传感测定中。

象形圖

Flame

訊號詞

Warning

危險聲明

危險分類

Flam. Sol. 2

儲存類別代碼

4.1B - Flammable solid hazardous materials

水污染物質分類(WGK)

WGK 3

個人防護裝備

Eyeshields, Faceshields, Gloves, type P3 (EN 143) respirator cartridges


从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Preparation and Spectral Properties of Mixed-Ligand Complexes of VO (IV), Ni (II), Zn (II), Pd (II), Cd (II) and Pb (II) with Dimethylglyoxime and N-Acetylglycine.
Shaker SA
Journal of Chemistry, 7(S1), S580-S586 (2010)
Dimethylglyoxime doped sol-gel carbon composite voltammetric sensor for trace nickel.
Wang J, et al.
Electroanalysis, 9(9), 689-692 (1997)
Application of adsorptive stripping voltammetry (AdSV) for the analysis of trace metals in brine.
Romanus A, et al.
Fresenius Journal of Analytical Chemistry, 340(6), 363-370 (1991)
Jacob P Thyssen et al.
The Science of the total environment, 409(22), 4663-4666 (2011-09-06)
Nickel and cobalt allergy remain frequent in dermatitis patients. It is important to determine possible nickel and cobalt exposures at work as these may offer important information to regulators and physicians who perform patch testing. Clinical relevance of metal exposure
Jacob P Thyssen et al.
Contact dermatitis, 62(5), 279-288 (2010-06-12)
The accuracy of the dimethylglyoxime (DMG) nickel spot test has been questioned because of false negative and positive test reactions. The EN 1811, a European standard reference method developed by the European Committee for Standardization (CEN), is fine-tuned to estimate

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门