Passa al contenuto
Merck
Tutte le immagini(1)

Documenti

P-906

Supelco

Prazepam solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula empirica (notazione di Hill):
C19H17ClN2O
Numero CAS:
Peso molecolare:
324.80
Numero CE:
Codice UNSPSC:
41116107
NACRES:
NA.24

Grado

certified reference material

Forma fisica

liquid

Caratteristiche

Snap-N-Spike®/Snap-N-Shoot®

Confezionamento

ampule of 1 mL

Produttore/marchio commerciale

Cerilliant®

drug control

Narcotic Licence Schedule B (Switzerland); psicótropo (Spain); Decreto Lei 15/93: Tabela IV (Portugal)

Concentrazione

1.0 mg/mL in methanol

tecniche

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

applicazioni

clinical testing

Formato

single component solution

Temperatura di conservazione

2-8°C

Stringa SMILE

Clc1ccc2N(CC3CC3)C(=O)CN=C(c4ccccc4)c2c1

InChI

1S/C19H17ClN2O/c20-15-8-9-17-16(10-15)19(14-4-2-1-3-5-14)21-11-18(23)22(17)12-13-6-7-13/h1-5,8-10,13H,6-7,11-12H2
MWQCHHACWWAQLJ-UHFFFAOYSA-N

Descrizione generale

Prazepam is a benzodiazepine prescribed for the short-term treatment of anxiety. Sold under the trade name Centrax, this drug also has anticonvulsant, sedative, and muscle relaxant effects. This Snap-N-Spike® Reference Solution is suitable for use in LC/MS or GC/MS applications for urine drug testing, clinical toxicology, or forensic analysis.

Note legali

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

Prodotti correlati

N° Catalogo
Descrizione
Determinazione del prezzo

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Organi bersaglio

Eyes,Central nervous system

Codice della classe di stoccaggio

3 - Flammable liquids

Classe di pericolosità dell'acqua (WGK)

WGK 1

Punto d’infiammabilità (°F)

49.5 °F - closed cup

Punto d’infiammabilità (°C)

9.7 °C - closed cup


Certificati d'analisi (COA)

Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

M Soyka et al.
Der Nervenarzt, 65(9), 628-632 (1994-09-01)
We report the case of a 61-year old patient with an affective disorder who had been treated with benzodiazepines in low dosages over a 16 year period. This treatment had been prescribed by his physician following several depressive episodes. During
X H Chen et al.
Journal of chromatography, 617(1), 147-151 (1993-07-23)
The lot-to-lot reproducibilities of Bond Elut Certify and Clean Screen DAU columns are described. The recoveries of five test drugs obtained from twelve lots of Bond Elut Certify columns ranged from 84 to 104% with standard deviations of less than
H L Tai et al.
Clinical biochemistry, 26(3), 165-171 (1993-06-01)
A simple, rapid high-pressure liquid chromatography (HPLC) method was developed for detecting and quantifying benzodiazepines in serum. Seven major benzodiazepines were extracted from spiked serum samples using solid-phase extraction with prazepam as the internal standard. The eluted drugs were then
François-Ludovic Sauvage et al.
Journal of separation science, 32(18), 3074-3083 (2009-08-22)
LC coupled to single (LC-MS) and tandem (LC-MS/MS) mass spectrometry is recognized as the most powerful analytical tools for metabolic studies in drug discovery. In this article, we describe five cases illustrating the utility of screening xenobiotic metabolites in routine
H A Archontaki et al.
Journal of pharmaceutical and biomedical analysis, 17(4-5), 739-750 (1998-07-31)
A reversed-phase HPLC method was developed for the kinetic investigation of the acidic hydrolysis of prazepam which was carried out in hydrochloric acid solutions of 0.01, 0.1 and 1.0 M. In addition, a fourth-order derivative method for monitoring the parent

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.