357790
Thianaphthene
98%
Sinonimo/i:
Benzo[b]thiophene, Benzothiophene, Thionaphthene
Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali
About This Item
Prodotti consigliati
Saggio
98%
Forma fisica
solid
P. eboll.
221-222 °C (lit.)
Punto di fusione
30-33 °C (lit.)
Densità
1.149 g/mL at 25 °C (lit.)
Stringa SMILE
c1ccc2sccc2c1
InChI
1S/C8H6S/c1-2-4-8-7(3-1)5-6-9-8/h1-6H
FCEHBMOGCRZNNI-UHFFFAOYSA-N
Cerchi prodotti simili? Visita Guida al confronto tra prodotti
Categorie correlate
Descrizione generale
Reaction of ethyl diazoacetate with thianaphthene has been reported.
Applicazioni
Thianaphthene may be used in the preparation of 2-thianapthenylphenyllithium, via metalation by n-butyllithium.
Avvertenze
Warning
Indicazioni di pericolo
Consigli di prudenza
Classi di pericolo
Acute Tox. 4 Oral - Aquatic Chronic 3
Codice della classe di stoccaggio
11 - Combustible Solids
Classe di pericolosità dell'acqua (WGK)
WGK 3
Dispositivi di protezione individuale
dust mask type N95 (US), Eyeshields, Faceshields, Gloves
Scegli una delle versioni più recenti:
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
I clienti hanno visto anche
Reactions of ethyl diazoacetate with thianaphthene, indoles, and benzofuran.
The Journal of Organic Chemistry, 42(24), 3945-3949 (1977)
Journal of colloid and interface science, 518, 149-155 (2018-02-18)
An adsorbent with multiple interaction sites for the adsorption of nitrogen-containing compounds (NCCs) has been realized in a silver ion functionalized Cr3+ based metal-organic framework (Cr)-MIL-101-SO3Ag. The adsorptive denitrogenation performance of (Cr)-MIL-101-SO3Ag was evaluated in a batch adsorption system in
Some 2-Substituted Thianaphthenes Derived from 2-Thianaphthenyllithium1.
Journal of the American Chemical Society, 74(3), 664-665 (1952)
Journal of chromatography. A, 1358, 145-154 (2014-07-21)
Linear gradient programs are very frequently used in reversed phase liquid chromatography to enhance the selectivity compared to isocratic separations. Multi-linear gradient programs on the other hand are only scarcely used, despite their intrinsically larger separation power. Because the gradient-conformity
Journal of chromatography. A, 1421, 154-161 (2015-04-25)
An improved multiple flame photometric detector (mFPD) is introduced, based upon interconnecting fluidic channels within a planar stainless steel (SS) plate. Relative to the previous quartz tube mFPD prototype, the SS mFPD provides a 50% reduction in background emission levels
Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..
Contatta l'Assistenza Tecnica.