Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

24010

Supelco

SP®-2250 Capillary GC Column

L × I.D. 30 m × 0.25 mm, df 0.20 μm

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41115710
eCl@ss:
32119290

Materiais

fused silica

Agency

meets requirements for USP G3

Parâmetros

0-250 °C temperature (isothermal or programmed)

Valor beta

313

df

0.20 μm

técnica(s)

gas chromatography (GC): suitable

C × D.I.

30 m × 0.25 mm

Grupo ativo da matriz

Non-bonded; poly(50% phenyl/50% methyl siloxane) phase

tipo de coluna

capillary intermediate polar

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Application: The SP-2250 column is a non-bonded 50% phenyl polymer. It is highly effective for the analysis of polar compounds.
USP Code: This column meets USP G3 requirements.
Phase:
  • Non-bonded
  • Poly(50% phenyl/50% methyl siloxane)
Temp. Limits:
  • 0 °C to 250 °C (isothermal or programmed)

Aplicação

Capillary column coated with SP®-2250 (methyl silicone-phenyl silicone, 1:1) stationary phase may be used in gas chromatographic analysis of azaarenes (benzacridines and dibenzacridines).

Outras notas

We offer a variety of chromatography accessories including analytical syringes

Informações legais

SP is a registered trademark of Sigma-Aldrich Co. LLC

Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

D F Tomkins
Journal - Association of Official Analytical Chemists, 70(6), 1056-1058 (1987-11-01)
An isothermal gas chromatographic method for measuring alachlor in Micro-Tech (microencapsulated) formulations was tested by 5 collaborators. The samples were prepared in acetone, and alachlor was determined using a gas chromatographic column of 10% SP-2250 on 100-120 mesh Supelcoport. Di-n-pentylphthalate
D J Greenblatt et al.
Anesthesiology, 55(2), 176-179 (1981-08-01)
Plasma midazolam concentrations following single therapeutic doses can be quantitated using electron-capture gas-liquid chromatography. After addition of a benzodiazepine analogue as an internal standard, samples are extracted with benzeneisoamyl alcohol (98.5:1.5). The organic extract is evaporated to dryness, reconstituted, and
J E Wallace et al.
Clinical chemistry, 25(7), 1296-1300 (1979-07-01)
We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.)
V Gambaro et al.
Journal of analytical toxicology, 6(6), 321-323 (1982-11-01)
The gas chromatographic identification of barbiturates isolated from biological material is not optimal, and due to their polar nature, it is difficult to obtain good resolution on most columns. To improve resolution, flash alkylation appeared to be a reasonable alternative.
D Courtot
British journal of sports medicine, 10(3), 143-146 (1976-10-01)
At the request of the Service des Haras, our laboratory works on the toxicological problems of the sport-horse. These studies have resulted in the setting up of an anti-doping control for equestrian competitions of various types, not only flat racing.

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica