Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

GE80-6484-51

2-D Clean-Up Kit

Cytiva 80-6484-51

Sinônimo(s):

2D Clean-Up Kit

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
41105323
NACRES:
NA.25

Características

wetted part: no

fabricante/nome comercial

Cytiva 80-6484-51

embalagem

pkg of 50 samples

Categorias relacionadas

Descrição geral

2-D Clean-Up Kit is designed to prepare samples for 2-D electrophoresis that otherwise produce poor 2-D spot-maps due to high conductivity, high levels of interfering substances, or low protein concentration. The reagents quantitatively precipitate proteins while leaving interfering substances, such as detergents, salts, lipids, phenolics, and nucleic acids, in solution.

Treatment of the sample with 2-D Clean-Up Kit can improve the quality of 2-D electrophoresis results, reducing streaking, background staining, and other artifacts due to interfering contaminants. The kit can make 2-D analysis possible for samples that are otherwise too dirty or too dilute.

The 2-D Clean-Up Kit procedure uses precipitant and co-precipitant in combination to quantitatively precipitate proteins. Precipitated proteins are pelleted by centrifugation and the precipitate is further washed to remove nonprotein contaminants. After a second centrifugation, the resultant pellet is resuspended into denaturing sample solution for first-dimension IEF.

The procedure can be completed in 90 min and does not result in spot gain or loss. The kit contains sufficient reagents to process 50 samples of up to 100 μ each. The procedure can be scaled up for larger volumes or more dilute samples.

2-D Clean-Up Kit increases labeling efficiency and protein abundance when using 2-D Fluorescence Difference Gel Electrophoresis (2-D DIGE).

Aplicação

Automated identification and quantitation of proteins and peptides using LC-MS/MS.

Características e benefícios

  • Improves the quality of 2-D electrophoresis results by removing interfering contaminants
  • Quantitative precipitation separates proteins from detergents, salts, lipids, phenolics and nucleic acids
  • Delivers quantitative yield in about 90 min.

Armazenamento e estabilidade

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
The wash buffer should be placed at -20 °C at least 1 h before use and may be s-red in a -20 °C freezer

Nota de análise

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Pictogramas

Environment

Palavra indicadora

Danger

Frases de perigo

Código de classe de armazenamento

8B - Non-combustible corrosive hazardous materials


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documentos section.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 3

1 of 3

Protocolos

Mini Dialysis Kit from GE Healthcare Lifescience is designed for the dialysis of small sample volumes with minimal handling and sample loss and reduces the pronounced streaking on 2-D gels caused by low-molecular-weight contaminants.

Sample Grinding Kit from GE Healthcare is designed to disrupt cell or tissue samples for protein extraction.

2-D Clean-Up Kit from GE Healthcare is designed to prepare samples that would otherwise produce poor 2-D results.

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica