Pular para o conteúdo
Merck
Todas as fotos(2)

Documentos Principais

GE28-9269-78

HiScreen Capto Q

Cytiva 28-9269-78

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
47101511
NACRES:
NA.56

ligand

quaternary amine

descrição

Ion Exchanger Type (value)

embalagem

pkg of 1 ea

fabricante/nome comercial

Cytiva 28-9269-78

Parâmetros

44 psi

tamanho do leito

7.7 mm × 100 mm

volume do leito

4.7 mL

D.I. da coluna

7.7 mm

Matriz

highly cross-linked agarose with dextran surface extender

diâmetro médio

90 μm (d50v)

cleaning

2-14

Faixa de trabalho

2-12

adequação

suitable for bioprocess medium

Descrição geral

HiScreen Capto Q is a column packed with a strong anion exchange modern resin, combining speed and capacity. Suitable for process development. The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, because the 10 cm bed height provides sufficient residence time. The results can then serve as a basis for linear process scale-up.

Cytiva′s resin couples a quaternary ammonium (Q) strong anion exchanger to a chemically modified, high-flow agarose matrix. The rigid agarose matrix provides greater particle rigidity without compromising pore size, which allows for high bed volume and purification of viscous samples at high flow rates.High dynamic binding capacity is achieved with a dextran surface extender that coats the agarose matrix. The resin’s high binding-capacity, high flow rate, and low back pressure reduce process cycle times and improve productivity at process scale.

Características e benefícios

  • Prepacked with Capto Q strong anion exchange chromatography resin.
  • Convenient method optimization and parameter screening because of the 10cm bed height.
  • These columns are easily connected in series to increase bed height to 20 cm.
  • Fast results and minimal consumption of sample and buffer consumption through the small bed volume.
  • BioProcess columns packed with the same chromatography resin and using the same linear fluid velocity can produce scalable, reproducible results.

Armazenamento e estabilidade

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol)

Nota de análise

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informações legais

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva

Pictogramas

Flame

Palavra indicadora

Warning

Frases de perigo

Código de classe de armazenamento

3 - Flammable liquids


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Lamentamos, não temos COA para este produto disponíveis online no momento.

Se precisar de ajuda, entre em contato Atendimento ao cliente

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica