Documentos

GE28-9269-79

HiScreen Capto S

Cytiva 28-9269-79

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
47101511
NACRES:
NA.56

ligand

sulfonate group

descrição

Ion Exchanger Type (value)

embalagem

pkg of 1 ea

fabricante/nome comercial

Cytiva 28-9269-79

Parâmetros

44 psi

tamanho do leito

7.7 mm × 100 mm

volume do leito

4.7 mL

D.I. da coluna

7.7 mm

matriz

highly cross-linked agarose with dextran surface extender

diâmetro médio

90 μm (d50v)

cleaning

3-14

working range

4-13

adequação

suitable for bioprocess medium

Descrição geral

HiScreen Capto S columns are prepacked with Capto S ion exchange chromatography medium, and are part of the process development platform available from Cytiva. The columns are an excellent choice for method optimization and parameter screening.

The small column volume of 4.7 mL and bed height of 10 cm make HiScreen columns excellent tools for method optimization, parameter screening, robustness testing, and convenient scale-up. Process fluid velocities can be applied, since the 10 cm bed height gives enough residence time and the results can then serve as basis for linear process scale-up.

If necessary, two columns can easily be connected in series to give a bed height of 2NA cm.

Media prepacked in HiScreen Capto IEX columns are also available in other formats and as bulk packs, which makes it possible to use the same media for development work, pilot studies, and routine production.

Características e benefícios

  • Capto S is a strong cation exchange BioProcess medium, designed to meet the demands of modern large-scale manufacturers for fast, efficient, and cost-effective capture and intermediate protein purification.
  • Prepacked, ready-to-use columns for convenient process development optimization.
  • 1NA cm bed height of HiScreen columns is designed to allow method optimization and parameter screening.
  • Easily connected in series to achieve 2NA cm bed height.
  • Small bed volume gives fast results and minimal sample/buffer consumption.
  • Reproducible results, scalable to BioProcess columns packed with the same media using the same linear fluid velocity.

Armazenamento e estabilidade

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (0.2 M sodium acetate in 20% ethanol)
Store at 4 to 30 °C (20% Ethanol + 0.2 M Sodium Acetate)

Nota de análise

To view the Certificate of Analysis for this product, please visit www.cytiva.com.

Informações legais

Capto is a trademark of Cytiva
HiScreen is a trademark of Cytiva

Pictogramas

Flame

Palavra indicadora

Warning

Frases de perigo

Código de classe de armazenamento

3 - Flammable liquids


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica