Pular para o conteúdo
Merck
Todas as fotos(3)

Documentos Principais

MSHMAG-21K

Millipore

MILLIPLEX® Multi-Species Hormone Magnetic Bead Panel

The Multi-Species Hormone Panel, using the Luminex xMAP technology, enables the simultaneous analysis of 5 steroid/thyroid biomarkers in human serum, plasma and cell culture samples.

Sinônimo(s):

luminex multiple species thyroid reproductive stress endocrine metabolic hormones multiplex assay, millipore multiple species metabolism hormones multiplex kit, multi species hormone immunoassay panel

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Código UNSPSC:
12161503
eCl@ss:
32161000
NACRES:
NA.47

Nível de qualidade

reatividade de espécies

human, canine

fabricante/nome comercial

Milliplex®

assay range

accuracy: 105%
(Canine Samples: T3)

accuracy: 80%
(Canine Samples: Estradiol)

accuracy: 85%
(Human Samples: Progesterone)

accuracy: 87%
(Canine Samples: T4)

sensitivity: 0.01 ng/mL
(MinDC+2SD; Estradiol)

sensitivity: 0.12 ng/mL
(MinDC+2SD; T3)

sensitivity: 0.25 ng/mL
(MinDC+2SD; Progesterone)

sensitivity: 0.33 ng/mL
(MinDC+2SD; Cortisol)

sensitivity: 0.51 ng/mL
(MinDC+2SD; T4)

standard curve range: 0.014-10 ng/mL
(Estradiol)

standard curve range: 0.07-50 ng/mL
(T3)

standard curve range: 0.14-100 ng/mL
(Progesterone)

standard curve range: 0.27-200 ng/mL
(Cortisol)

standard curve range: 0.34-250 ng/mL
(T4)

inter-assay cv: <10%
intra-assay cv: <10%
(Cortisol)

inter-assay cv: <15%
intra-assay cv: <10%
(Estradiol)

inter-assay cv: <15%
intra-assay cv: <10%
(Progesterone)

inter-assay cv: <15%
intra-assay cv: <10%
(T3)

inter-assay cv: <15%
intra-assay cv: <10%
(T4)

técnica(s)

multiplexing: suitable

método de detecção

fluorometric (Luminex xMAP)

Condições de expedição

ambient

Descrição geral

Steroid and thyroid hormones are small molecule endocrine hormones secreted from adrenal glands (cortisol), ovaries (estradiol and progesterone), and the thyroid (T3 and T4). These hormones play key roles in the regulation of energy balance, mental and physical development, sex organ development, reproduction, and pregnancy. These hormones play a role in the patho-physiology of many diseases such as thyroid-related diseases (Grave’s disease and hyper/hypothyroidism), steroid-related diseases (Cushing’s syndrome) and stress related diseases. Endocrine disrupting chemincals (EDC) can impact normal functioning of steroid and thyroid hormones.

The MILLIPLEX® Multi-Species Hormone Panel is a 5-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma and cell/tissue culture samples: Cortisol, Estradiol, Progesterone, T3 and T4. This multi-species kit may be used to detect these analytes in human, dog, rat, mouse, cynomolgous monkey, rhesus monkey, horse, rabbit, cat, guinea pig, pig and hamster. The kit has been verified with human and canine samples. The amount of cross-reactivity to other species has been confirmed, but not tested to the same level of verification as was used for human and canine. All analytes in this kit are run in a competitive assay format. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Endocrine

Especificidade

Approximately 10% cross-reactivity to Cortisol is observed in the Progesterone assay and approximately 5% cross-reactivity to T3 is observed in the T4 assay. No other significant cross-reactivity is observed within the panel or to other similar analytes.

This multi-species kit may be used to detect these 5 analytes in human, dog, rat, mouse, cynomolgous monkey, rhesus monkey, horse, rabbit, cat, guinea pig, pig and hamster. However, the kit was fully validated with human and canine samples only and the amount of cross-reactivity to other species tested has not been determined.
Cross Reactivty
Approximately 10% cross-reactivity to Cortisol is observed in the Progesterone assay and approximately 5% cross-reactivity to T3 is observed in the T4 assay. No other significant cross-reactivity is observed within the panel or to other similar analytes.

Aplicação

  • Analytes: Cortisol, Estradiol, Progesterone, T3, T4
  • NOTE: This multi-species kit may be used to detect these analytes in human, dog, rat, mouse, cynomolgus monkey, rhesus monkey, horse, rabbit, cat, guinea pig, pig and hamster. However, the kit was validated with human and canine samples only and the amount of cross-reactivity to other species tested, has not been determined.
  • NOTE: This assay requires an extraction step for serum and plasma samples (instructions are provided in the kit protocol).
  • NOTE: This is a competitive immunoassay
  • Recommended Sample Type: Serum, plasma, or tissue/cell culture supernatants or lysates from multiple species
  • Recommended Sample Dilution: 25 μL per well of undiluted extracted serum or plasma. Tissue/cell culture samples may be run neat or diluted in an appropriate control media.
  • Assay Run Time: Overnight (16-20 hours) at 2-8°C.
  • Research Category: Metabolism
  • Research Category: Endocrine

Características e benefícios

Design your multiplex kit by choosing available analytes within this panel.

Embalagem

96 well plate
Everything you need in a single kit.

Ligação

Replaces: STTHMAG-21K

Armazenamento e estabilidade

Recommended storage for kit components is 2 - 8°C.

Outras notas

Please contact Technical Service for linearity of dilution.

Informações legais

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Exoneração de responsabilidade

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Palavra indicadora

Danger

Classificações de perigo

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

Órgãos-alvo

Respiratory Tract

Código de classe de armazenamento

10 - Combustible liquids

Classe de risco de água (WGK)

WGK 3


Certificados de análise (COA)

Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Gabriela Leite et al.
Menopause (New York, N.Y.), 29(3), 264-275 (2022-02-26)
Hormone therapy (HT) is used to treat menopause-related conditions and symptoms. The small intestine plays key roles in metabolic and endocrine function, but the effects of HT on the small intestinal microbiome are unknown. Here, we characterize duodenal microbiome differences
Christian K Garcia et al.
PloS one, 17(10), e0275715-e0275715 (2022-10-14)
The capability of male mice to exercise in hot environments without succumbing to exertional heat stroke (EHS) is markedly blunted compared to females. Epidemiological evidence in humans and other mammals also suggests some degree of greater vulnerability to heat stroke

Conteúdo relacionado

The newer xMAP® Sheath Fluid PLUS formulation contains 3 modes of microbial action to eliminate potential environmental microbial resistance. See how the preparations compare in this performance comparison of the previous xMAP® Sheath Fluid to the new xMAP® Sheath Fluid PLUS formulation in MILLIPLEX® multiplex assays.

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

Learn the benefits of using biomarker detection multiplex immunoassays for laboratory, companion, and agricultural animal research and explore MILLIPLEX® multiplex assays for veterinary medicine and animal health research.

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica