The analytes available for this multiplex kit are: Liver-type arginase 1 (ARG1), α-glutathianone S-transferase (GSTα), malate dehydrogenase 1 (MDH1), sorbitol dehydrogenase (SDH), and 5′-Nucleotidase (5′-NT/CD73).
Nível de qualidade
100
200
reatividade de espécies
human
fabricante/nome comercial
Milliplex®
assay range
accuracy: 106-123%
standard curve range: 14-10,000 pg/mL
(GSTα)
standard curve range: 41-30,000 pg/mL
(5′-NT/CD73)
standard curve range: 549-400,000 pg/mL
(SDH)
standard curve range: 69-50,000 pg/mL
(ARG1)
standard curve range: 69-50,000 pg/mL
(MDH1)
técnica(s)
multiplexing: suitable
método de detecção
fluorometric (Luminex xMAP)
Condições de expedição
ambient
Descrição geral
The MILLIPLEX® Human Liver Injury Panel contains all the components necessary to simultaneous quantify the following 5 analytes in serum and plasma samples:
• Liver-Type Arginase 1 (ARG1)*
• Malate dehydrogenase 1 (MDH1)*
• α-glutathione S-transferase (GSTα)*
• Sorbitol Dehydrogenase (SDH)*
• 5′-Nucleotidase/CD73 (5′-NT)
*ARG1, GSTα, and SDH are biomarkers listed in the Predictive Safety Testing Consortium (PSTC) project pipeline which have a strong translational role in drug safety testing.
The MILLIPLEX® portfolio offers the broadest selection of analytes across a wide range of disease states and species. Once the analytes of interest have been identified, you can rely on the quality that we build into each kit to produce results you can trust. In addition to the assay characteristics listed in the protocol, other performance criteria evaluated during the validation process include: cross-reactivity, dilution linearity, kit stability, and sample behavior (e.g. detectability and stability).
Panel Type: Toxicity
Especificidade
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.
Aplicação
- Analytes: ARG1, GSTα, SDH 5′-NT/CD73, Malate dehydrogenase 1 (MDH1)
- Recommended Sample type: serum, plasma, and tissue culture supernatants
- Recommended Sample dilution: 1:5 serum or plasma samples. Tissue culture supernatants may require dilution as well.
- Assay Run Time: One day or Overnight
- Research Category: Toxicity
Características e benefícios
Embalagem
Armazenamento e estabilidade
Outras notas
Informações legais
Exoneração de responsabilidade
Palavra indicadora
Danger
Frases de perigo
Declarações de precaução
Classificações de perigo
Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Skin Sens. 1
Código de classe de armazenamento
6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects
Classe de risco de água (WGK)
WGK 3
Certificados de análise (COA)
Busque Certificados de análise (COA) digitando o Número do Lote do produto. Os números de lote e remessa podem ser encontrados no rótulo de um produto após a palavra “Lot” ou “Batch”.
Já possui este produto?
Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.
Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.
Entre em contato com a assistência técnica