53572-U
Ascentis® Express 90 Å PFAS (2.7 μm) Delay HPLC Columns
L × I.D. 5 cm × 3.0 mm, HPLC Delay Column; suitable for PFAS testing
Synonym(s):
Ascentis® Express 90 Å PFAS Delay, 2.7 μm HPLC Column
About This Item
Recommended Products
Product Name
Ascentis® Express 90 Å PFAS Delay, 2.7 μm HPLC Column, column L × I.D. 5 cm × 3.0 mm, suitable for PFAS testing
material
stainless steel column
Quality Level
agency
suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for EPA OTM-45
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010
suitable for USP L62
reg. compliance
suitable for FDA C-010.02
product line
Ascentis®
feature
endcapped
packaging
1 ea of
parameter
≤60 °C temp. limit
≤9000 psi max. pressure (600 bar)
technique(s)
HPLC: suitable
LC/MS: suitable
column L × I.D.
5 cm × 3.0 mm
surface area
135 m2/g
matrix
Fused-Core® silica particle platform particle platform
superficially porous particle
matrix active group
highly retentive endcapped silane bonding phase
particle size
2.7 μm
pore size
90 Å pore size
operating pH range
2-9
application(s)
PFAS testing
separation technique
reversed phase
Looking for similar products? Visit Product Comparison Guide
General description
Legal Information
Choose from one of the most recent versions:
Certificates of Analysis (COA)
Don't see the Right Version?
If you require a particular version, you can look up a specific certificate by the Lot or Batch number.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
LC-MS method-based separation and determination of 32 short-chain and long-chain PFAS (Per- and poly-fluoroalkyl substances) compounds from drinking water following 3 EPA methods Method 533, 537, and 537.1. EPA 8327
Liquid Chromatography–Mass Spectrometry (LC-MS) separation of 33 PFAS (Per- and poly-fluoroalkyl substances) using a superficially porous silica particles (SPP) based Ascentis® Express C18 column.
This page provides tables that list the products used in promulgated methods for Per- and polyfluoroalkyl substances (PFAS) analysis, organized by method and step for easy reference. As new methods are released, this page will be updated.
Global Trade Item Number
SKU | GTIN |
---|---|
53572-U | 4065266561456 |
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service