跳轉至內容
Merck
全部照片(1)

重要文件

PIR00

Sigma-Aldrich

Inhibitor Resistant Genotyping PCR ReadyMix

for Bio-Rad, Cepheid, Eppendorf, Illumina, Corbett, and Roche systems

同義詞:

Inhibitor Resistant Genotyping PCR ReadyMix

登入查看組織和合約定價


About This Item

分類程式碼代碼:
41106300
NACRES:
NA.55

品質等級

形狀

liquid

用途

sufficient for 1250 reactions
sufficient for 250 reactions
sufficient for 5000 reactions

特點

Difficult Templates/Specialty Enzymes PCR
dNTPs included
hotstart

儲存條件

protect from light

技術

qPCR: suitable

顏色

light blue

輸入

crude DNA

相容性

Bio-Rad CFX384
Bio-Rad CFX96
Bio-Rad MJ Chromo4
Bio-Rad MJ Opticon 2
Bio-Rad MJ Opticon
Bio-Rad MiniOpticon
Cepheid SmartCycler
Eppendorf® Mastercycler ep realplex
Eppendorf® Mastercycler ep realplex2 S
Illumina Eco qPCR
Qiagen Corbett Rotor-Gene 3000
Qiagen Corbett Rotor-Gene 6000
Qiagen Corbett Rotor-Gene Q
Roche LightCycler 480

檢測方法

probe-based

運輸包裝

dry ice

儲存溫度

−20°C

尋找類似的產品? 前往 產品比較指南

一般說明

Inhibitor Resistant Genotyping PCR Readymix is a 2X concentrated ready-to-use master mix for PCR amplification of DNA templates that overcomes inhibitors often present in crude samples extracted from environmental specimens, plant tissues, or animal tissues. It is a versatile and robust PCR reagent that provides highly specific and efficient amplification for genotyping sequence variants including allelic discrimination of single nucleotide polymorphisms (SNPs) using a variety of fluorogenic probe chemistries, including TaqMan® hydrolysis probes. Inhibitor Resistant Genotyping PCR Readymix contains all required reaction components, except primers, probes, and DNA template. The light blue color of the inert tracer dye simplifies reaction assembly in white, or clear, plates and helps to minimize pipetting or mixing errors. It does not interfere with reporter dye fluorescence or affect the stability of the product.

A key component of Inhibitor Resistant Genotyping PCR ReadyMix is an ultra-pure, highly processive thermostable DNA polymerase that is combined with high avidity monoclonal antibodies. This proprietary polymerase mix is highly resistant to PCR inhibitors and provides an extremely stringent automatic hot-start allowing reaction assembly, and temporary storage, at room temperature prior to PCR amplification.

應用

Different real-time PCR systems employ different strategies for normalization of fluorescent signals and correction of well-to-well optical variations. It is critical to match the appropriate qPCR reagent to your specific instrument.KiCqStart® One-Step Probe RT-qPCR ReadyMix does not contain an internal reference dye.
Inhibitor Resistant Genotyping PCR ReadyMix has been used as a component of the reaction mixture for detection of leucoanthocyanidin reductase(PaLAR3) alleles in a genotyping assay and multiplex PCR for amplification of microsatellite.

特點和優勢

  • Assay results in as little as 33 minutes
  • Highly efficient and sensitive real-time PCR results
  • Little/no optimization required
  • Compatible with both fast and conventional PCR cycling protocols

成分

2X reaction buffer containing optimized concentrations of MgCl2, dNTPs (dATP, dCTP, dGTP, dTTP), hot-start DNA polymerase, insert blue qPCR dye, and stabilizers.

packaging:
250 reactions* = 2 X 1.25 mL tubes
1250 reactions* = 10 X 1.25 mL tubes
5000 reactions* = 1 X 50 mL tube
*number of reactions based on a 20uL volume

其他說明

Compatible instruments include:
  • Bio-Rad® CFX384
  • Bio-Rad CFX96
  • Bio-Rad MiniOpticon
  • Bio-Rad/MJ Chromo4
  • Bio-Rad/MJ Opticon 2
  • Bio-Rad/MJ Opticon
  • Cepheid SmartCycler®
  • Eppendorf Mastercycler® ep realplex
  • Eppendorf Mastercycler ep realplex2 s
  • Illumina Eco qPCR
  • Qiagen/Corbett Rotor-Gene® 3000
  • Qiagen/Corbett Rotor-Gene 6000
  • Qiagen/Corbett Rotor-Gene Q
  • Roche LightCycler® 480

法律資訊

Bio-Rad is a registered trademark of Bio-Rad Laboratories, Inc.
CFX384 is a trademark of Bio-Rad Laboratories, Inc.
CFX96 is a trademark of Bio-Rad Laboratories, Inc.
Chromo4 is a trademark of Bio-Rad Laboratories, Inc.
Eppendorf is a registered trademark of Eppendorf AG
KiCqStart is a registered trademark of QIAGEN Beverly Inc.
LightCycler is a registered trademark of Roche
Mastercycler is a registered trademark of Eppendorf AG
MiniOpticon is a trademark of Bio-Rad Laboratories, Inc.
Opticon is a trademark of Bio-Rad Laboratories, Inc.
ReadyMix is a trademark of Sigma-Aldrich Co. LLC
Rotor-Gene is a registered trademark of Qiagen GmbH
SmartCycler is a registered trademark of Cepheid, Inc.
TaqMan is a registered trademark of Roche Molecular Systems, Inc.

儲存類別代碼

12 - Non Combustible Liquids

水污染物質分類(WGK)

WGK 3

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析證明 (COA)

輸入產品批次/批號來搜索 分析證明 (COA)。在產品’s標籤上找到批次和批號,寫有 ‘Lot’或‘Batch’.。

已經擁有該產品?

您可以在文件庫中找到最近購買的產品相關文件。

存取文件庫

Root Rot Resistance Locus PaLAR3 Is Delivered by Somatic Embryogenesis (SE) Pipeline in Norway Spruce (Picea abies (L.) Karst.)
Edesi J, et al.
Forests, 12(2), 193-193 (2021)

我們的科學家團隊在所有研究領域都有豐富的經驗,包括生命科學、材料科學、化學合成、色譜、分析等.

聯絡技術服務