KTGRA02HH3
Aervent® 0.2 µm, Opticap® XL Capsule
Opticap® XL 2, pore size 0.2 μm, non-sterile, sterilization compatible with autoclavable, hydrophobic, 14 mm (9/16 in.) inlet/outlet hose barb
Synonym(s):
Opticap Sterilizing Grade XL2 Aervent 0.2 µm 9/16 in. HB/HB
About This Item
Recommended Products
material
PTFE
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal
Quality Level
sterility
non-sterile
sterilization compatibility
autoclavable compatible
product line
Opticap® XL 2
feature
hydrophobic
manufacturer/tradename
Opticap®
parameter
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
2.8 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
4.1 bar max. differential pressure (60 psid) at 25 °C (Reverse; intermittent)
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure
technique(s)
gas filtration: suitable
L
5.6 in.
W
3.3 in.
cartridge nominal length
5.5 in. (14.0 cm)
diam.
8.4 cm (3.3 in.)
filtration area
0.1 m2
inlet connection diam.
9/16 in.
inlet to outlet W
14.0 cm (5.5 in.)
outlet connection diam.
9/16 in.
impurities
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
gravimetric extractables
≤15 mg
matrix
Aervent®
pore size
0.2 μm pore size
bubble point
≥1100 mbar (16 psig), nitrogen with 70/30% IPA/water at 23 °C
fitting
14 mm (9/16 in.) inlet/outlet hose barb
Looking for similar products? Visit Product Comparison Guide
General description
Packaging
Linkage
Preparation Note
30 autoclave cycles of 30 min @ 135 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
Other Notes
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer Steam Sterilization & Integrity Testing Procedures guide and first page of Visual Inspection Guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Legal Information
Disclaimer
Not finding the right product?
Try our Product Selector Tool.
Certificates of Analysis (COA)