Przejdź do zawartości
Merck

I7638

Sigma-Aldrich

Indoxyl β-D-glucuronide cyclohexylammonium salt

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Wzór empiryczny (zapis Hilla):
C14H15NO7 · C6H13N
Numer CAS:
Masa cząsteczkowa:
408.45
Numer MDL:
Kod UNSPSC:
12352201
Identyfikator substancji w PubChem:
NACRES:
NA.25

Próba

≥98%

Postać

powder

aktywność optyczna

[α]20/D -80.0±5.0

metody

HPLC: suitable

temp. przechowywania

−20°C

ciąg SMILES

OC1C(OC(C(O)C1O)C(O)=O)Oc2c[nH]c3ccccc23

InChI

1S/C14H15NO7/c16-9-10(17)12(13(19)20)22-14(11(9)18)21-8-5-15-7-4-2-1-3-6(7)8/h1-5,9-12,14-18H,(H,19,20)

Klucz InChI

KUYNOZVWCFXSNE-UHFFFAOYSA-N

Kod klasy składowania

11 - Combustible Solids

Klasa zagrożenia wodnego (WGK)

WGK 3

Temperatura zapłonu (°F)

Not applicable

Temperatura zapłonu (°C)

Not applicable


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

S Agatsuma et al.
Clinical nephrology, 45(4), 250-256 (1996-04-01)
The content of indoxyl-beta-D-glucuronide, which has been found in patients' plasma as a new indicator of renal failure, logarithmically correlated with that of 3-indoxyl sulfate (indican) in the plasma of hemodialysis patients, showing another weak correlation with beta(2)-microglobulin content. The
T Niwa et al.
Nephron, 74(1), 72-78 (1996-01-01)
We identified and quantified indoxyl-beta-D-glucuronide in uremic serum and urine to determine the metabolism of indoles including indoxyl sulfate in uremic patients. Serum levels of indoxyl-beta-D-glucuronide were markedly increased in undialyzed uremic patients, in patients on hemodialysis, and in patients
J R Haines et al.
Applied and environmental microbiology, 59(8), 2758-2759 (1993-08-01)
Indoxyl-beta-D-glucuronide (indoxyl) was evaluated as a specific chromogen for detection of Escherichia coli by the membrane filter method. In all, 413 colonies were tested from the indoxyl-supplemented media, yielding 93.3% confirmation, as E. coli. Compared with the indoxyl medium, other
S Agatsuma et al.
Clinical chemistry, 40(8), 1580-1586 (1994-08-01)
Characteristic light emission induced by the oxidation of hydroxyl radicals has been found in plasma of hemodialysis patients (Agatsuma et al., Clin Chem 1992;38:48-55). We purified a primary emitter, a chemiluminescent component peaking at 430 nm, by anion-exchange chromatography and
S Fujita et al.
Rinsho byori. The Japanese journal of clinical pathology, 44(9), 895-898 (1996-09-01)
To establish a simple identification procedure for Escherichia coli, we developed a disk containing indoxyl-beta-D-glucuronide, the chromogenic substrate of beta-D-glucuronidase. Of 188 isolates of Enterobacteriaceae, 101 (97%) of 104 strains of E. coli and two (67%) of three strains of

Produkty

Today, diverse studies report the benefits of probiotics, such as inhibitory effects on pathogens, aid in the management or prevention of chronic intestinal inflammatory diseases or atopic syndromes, and support to the immune system. Potential beneficial applications abound, researchers continue to evaluate the effictiveness and clarify the mechanisms of action of probiotics.

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej