GE17-1181-01
RESOURCE™ RPC
Cytiva 17-1181-01, pack of 1 mL
Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych
About This Item
Polecane produkty
ligand
matrix surface
Właściwości
autoclavable 20 min at 121°C
opakowanie
pack of 1 mL
producent / nazwa handlowa
Cytiva 17-1181-01
Parametry
flow rate
580 psi
wymiary złoża
6.4 mm × 30 mm
objętość złoża
1 mL
macierz
polystyrene/divinylbenzene
śr. rozm. cząst.
15 μm (monosized)
cleaning
1-14
working range
1-12
pojemność
~10 mg binding capacity
przydatność
suitable for bioprocess medium
Opis ogólny
RESOURCE™ RPC are prepacked SOURCE™ 15RPC columns designed for rapid screening experiments, method development, and small-scale protein purification using reversed phase chromatography.
~10 mg BSA /ml medium at 300 cm/h, ~30 mg bacitracin/ml medium at 300 cm/h, ~50 mg insulin/ml medium at 300 cm/h
Zastosowanie
SOURCE™ 15RPC is based on rigid, monosized 15 μm diameter polystyrene/divinyl benzene beads. The matrix has outstanding selectivity for RPC. The monodispersity of the beads yields stable beds, Low back pressures and excellent results at high flow rates.With its high physical and chemical stability and very high batch-to-batch reproducibility, SOURCE™ 15RPC is well suited for all stages of an industrial scale operation - from research and process development through scale-up and into production. SOURCE™ 15RPC offers properties superior to those of other polymeric matrices.
Cechy i korzyści
- Wide pH range (1-12), outstanding selectivity, chemical resistance, high capacity, and high resolution at high flow rates.
- Excellent scalability, from RESOURCE™ to FineLINE columns.
- using ÄKTATM design and other high-performance liquid chromatography systems.
Przechowywanie i stabilność
Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.
Store at 4 to 30 °C (20% Ethanol or 70% Acetonitrile)
Komentarz do analizy
To view the Certificate of Analysis for this product, please visit www.cytiva.com.
Inne uwagi
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
Informacje prawne
RESOURCE is a trademark of Cytiva
SOURCE is a trademark of Cytiva
This page may contain text that has been machine translated.
Hasło ostrzegawcze
Warning
Zwroty wskazujące rodzaj zagrożenia
Zwroty wskazujące środki ostrożności
Kod klasy składowania
3 - Flammable liquids
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej