Kluczowe dokumenty
KHGEA2ZTH1
Millipore Express® SHC, Opticap® XLT Capsule
Opticap® XLT 20, inlet connection diam. 1.5 in., pore size 0.5/0.2 μm, cartridge nominal length 20 in. (50 cm)
Synonim(y):
Autoclavable Opticap XLT 20 Millipore Express SHC 0.5/0.2 μm TC/HB 1pk w/gauge port
About This Item
Polecane produkty
Materiały
polyethersulfone
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
polysulfone
silicone seal
Poziom jakości
zgodność regionalna
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterylność
non-sterile
Kompatybilność ze sterylizacją
autoclavable compatible
linia produktu
Opticap® XLT 20
Właściwości
hydrophilic
producent / nazwa handlowa
Millipore Express®
Parametry
1.0 bar max. inlet pressure (15 psi) at 80 °C
1000 bar max. differential pressure (15 psi) at 80 °C (Forward)
2.75 bar max. inlet pressure (40 psi) at 60 °C
2100 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent)
25 °C max. inlet temp.
5.5 bar max. inlet pressure (80 psi) at 25 °C
5500 mbar max. differential pressure (80 psi) at 25 °C (Forward)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
6900 mbar max. differential pressure (100 psi) at 25 °C (Forward; intermittent)
80 psig max. inlet pressure
metody
sterile filtration: suitable
Długość
61.1 cm (24.0 in.)
Szerokość
7.8 in.
długość nominalna kartridża
20 in. (50 cm)
Średnica
19.8 cm (7.8 in.)
powierzchnia filtracyjna
0.98 m2
śr. przyłącza doprowadzającego
1.5 in.
śr. przyłącza odprowadzającego
5/8 in.
zanieczyszczenia
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
macierz
Millipore Express® SHC
pore size
0.5/0.2 μm pore size
punkt pęcherzykowania
≥4000 mbar (58 psig), air with water at 23 °C
dopasowywanie
3/4 in. gauge port (T-Line Side)
inlet sanitary flange
outlet hose barb
1/4 in. vent hose barb (with double O-ring Seal)
(38 mm (1 1/2 in.) Sanitary Flange Inlet and 16 mm (5?8 in.) Hose Barb Outlet)
Opis ogólny
Opakowanie
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
3 autoclave cycles of 60 min @ 126 °C; not in-line steam sterilizable
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 40 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informacje prawne
Oświadczenie o zrzeczeniu się odpowiedzialności
Nie możesz znaleźć właściwego produktu?
Wypróbuj nasz Narzędzie selektora produktów.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej