Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Key Documents

KGW6A3TTT1

Millipore

Polysep II 1.0/0.5 µm nominal, Opticap® XLT Capsule

inlet connection diam. 1.5 in., Opticap® XLT 30, pore size 1.0/0.5 μm, cartridge nominal length 30 in. (75 cm)

Synonim(y):

Opticap XLT30 Polysep II 1.0/0.5 μm 1-1/2 in. TC

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
23151806
eCl@ss:
32031610

Materiały

borosilicate glass fiber (BGF) membrane
mixed cellulose esters (MCE) membrane
polypropylene
polypropylene housing
polypropylene support
polypropylene vent cap
silicone seal

Poziom jakości

zgodność regionalna

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterylność

non-sterile

Kompatybilność ze sterylizacją

autoclavable compatible

linia produktu

Opticap® XLT 30

Właściwości

hydrophilic

producent / nazwa handlowa

Opticap®

Parametry

1.0 bar max. inlet pressure (15 psi) at 80 °C
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
3.5 bar max. differential pressure (50 psid) at 25 °C
5.5 bar max. inlet pressure (80 psi) at 23 °C
80 psig max. inlet pressure

metody

prefiltration: suitable

Długość

87.1 cm (34.3 in.)

długość nominalna kartridża

30 in. (75 cm)

powierzchnia filtracyjna

1.38 m2

śr. przyłącza doprowadzającego

1.5 in.

szer. od złącza doprowadzającego do złącza odprowadzającego

15.2 cm (6.0 in.)

śr. przyłącza odprowadzającego

1.5 in.

zanieczyszczenia

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

substancje ekstrahujące się grawimetrycznie

≤435 mg/capsule

macierz

Polysep II

pore size

1.0/0.5 μm nominal pore size
1.0/0.5 μm pore size

moc wejściowa

sample type liquid

dopasowywanie

inlet sanitary flange
outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)

Szukasz podobnych produktów? Odwiedź Przewodnik dotyczący porównywania produktów

Opis ogólny

Device Configuration: Capsule
T-line/Gauge Port: T-line

Cechy i korzyści

Format: Double Layer

Opakowanie

Double Easy-Open bag

Inne uwagi

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the first page of Visual Inspection Guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Uwaga dotycząca przygotowania

Sterilization Method
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Komentarz do analizy

Gravimetric Extractables: after a 15 L flush and 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L

Informacje prawne

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
Polysep is a trademark of Sigma-Aldrich Co. LLC
This page may contain text that has been machine translated.

Nie możesz znaleźć właściwego produktu?  

Wypróbuj nasz Narzędzie selektora produktów.

Kod klasy składowania

11 - Combustible Solids

Klasa zagrożenia wodnego (WGK)

WGK 2


Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej