Kluczowe dokumenty
CHVE72TS3
Millipore Express® SHR with prefilter 0.5/0.1µm Cartridge 20
Code 7 Silicone, Autoclavable and SIP
Synonim(y):
Millipore Express SHR Cartridge Filter 20 in. 0.5/0.1 μm Code 7 Silicone
About This Item
Polecane produkty
Nazwa produktu
Millipore Express® SHRP, Cartridge, pore size 0.5/0.1 μm, cartridge nominal length 20 in. (50 cm), Code 7, silicone seal
Materiały
polyethersulfone
polypropylene
polypropylene support
polysulfone
silicone seal
Poziom jakości
zgodność regionalna
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterylność
non-sterile
Kompatybilność ze sterylizacją
autoclavable compatible
steam-in-place compatible
linia produktu
Millipore Express®
Właściwości
hydrophilic
producent / nazwa handlowa
Millipore Express®
Parametry
≤54.2 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C ( in water)
0.07 bar max. differential pressure (1 psi) at 135 °C (Reverse)
0.35 bar max. differential pressure (5 psi) at 135 °C (Forward)
1.0 psi max. differential pressure (69 mbar) at 135 °C (reverse)
1.7 bar max. differential pressure (25 psi) at 80 °C (Forward)
100 psi max. differential pressure (6.9 bar) at 25 °C (forward)
15 psi max. differential pressure (1.0 bar) at 135 °C (forward)
2.07 bar max. differential pressure (30 psi) at 25 °C (Reverse)
25 psi max. differential pressure (1.7 bar) at 80 °C (forward)
30 psi max. differential pressure (2.1 bar) at 25 °C (reverse)
6.9 bar max. differential pressure (100 psi) at 25 °C (Forward)
metody
sterile filtration: suitable
Długość
20 in.
Szerokość
2.7 in.
długość nominalna kartridża
20 in. (50 cm)
Średnica
6.9 cm (2.7 in.)
powierzchnia filtracyjna
0.98 m2
zanieczyszczenia
≤0.25 EU/mL (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
Matryca
Millipore Express® SHR (w/Prefilter)
pore size
0.5/0.1 μm pore size
moc wejściowa
sample type liquid
punkt pęcherzykowania
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
kod wkładu
Code 7
Opis ogólny
Opakowanie
Inne uwagi
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer wetting instructions of Filters with MILLIPORE EXPRESS® Membrane user guide
- Storage Statement: Please refer Filters with MILLIPORE EXPRESS® Membrane user guide
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
Uwaga dotycząca przygotowania
25 forward or 22 forward and 3 reverse SIP cycles of 30 min @ 135 °C, or 3 forward cycles, 30 min., 135 °C at ≤ 1000 mbar (15 psid); 25 autoclave cycles of 60 min @ 126 °C
Komentarz do analizy
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 40 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Informacje prawne
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej