콘텐츠로 건너뛰기
Merck
모든 사진(2)

주요 문서

GE29-0491-04

HiTrap® MabSelect SuRe

Cytiva 29-0491-04, pack of 1 mL

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151816
NACRES:
NA.56

ligand

alkali-stabilized protein A-derived (E. coli)

포장

pack of 1 mL

제조업체/상표

Cytiva 29-0491-04

재고 정보

not available in North America

저장 조건

(20% Ethanol)
(20% Ethanol, 0.1 M Potassium Phosphate buffer, pH 8.0)

파라미터

42 psi

베드 크기

7 mm × 25 mm

베드 용적

1 mL

컬럼 I.D.

7 mm

Matrix

highly cross-linked agarose

평균 부품 크기

85 μm (d₅₀v is the median particle size of the cumulative volume distribution)

cleaning

2-13.7

작동 범위

3-12

용량

≥30 mg binding capacity (humanlgG/ml at 2.4 min residence time)

적합성

suitable for bioprocess medium

저장 온도

2-8°C

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.
HiTrap MabSelect SuRe columns are prepacked with MabSelect SuRe, a BioProcess medium for purification of monoclonal antibodies from large sample volumes. The novel alkali-tolerant recombinant Protein A ligand allows cleaning-in-place (CIP).
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.

특징 및 장점

  • Withstands rigorous CIP and sanitization procedures with 0.1 to 0.5 M NaOH.
  • Novel ligand design gives enhanced protease resistance resulting in lower ligand leakage.
  • Oriented coupling of recombinant Protein A to the matrix via an engineered C-terminal cysteine enhances IgG binding capacity.
  • Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification.
  • Prepacked HiTrap columns for process development, screening of purification conditions, and small-scale purification of Mabs.

저장 및 안정성

Please be aware this product may be shipped 90 days before the expiration date. For more information on the batch specific expiration date, please contact technical service.

기타 정보

The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

법적 정보

Free MabSelect SuRe Ligand
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
HiTrap is a registered trademark of Cytiva
MabSelect SuRe is a trademark of Cytiva

픽토그램

Flame

신호어

Warning

유해 및 위험 성명서

Storage Class Code

3 - Flammable liquids


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

문서

This page shows how to perform sample desalting and buffer exchange for affinity chromatography of antibodies.

프로토콜

This page shows how to separate IgG antibodies by affinity chromatography using MabSelect Sure from GE Healthcare.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.