추천 제품
material
polyethylene cap
polyethylene liner
polypropylene tube
regenerated cellulose membrane
regenerated cellulose support
styrene-butadiene housing
Quality Level
무균
non-sterile
제품 라인
Amicon®
제조업체/상표
Amicon® Ultra
파라미터
15 mL sample volume
기술
protein extraction: suitable
protein purification: suitable
길이
12.1 cm (4.807 in.)
직경
2.97 cm
여과 면적
7.6 cm2
용적
15 mL
공극 크기
30 kDa MWCO
배송 상태
ambient
일반 설명
The vertical design and available membrane surface area provide fast sample processing, high sample recovery (typically greater than 90% of dilute starting solution), and the capability for 80-fold concentration. Solute polarization and subsequent fouling of the membrane are minimized by the vertical design, and a physical deadstop in the filter device prevents spinning to dryness and potential sample loss.
The concentrate is collected from the filter device sample reservoir using a pipetter, while the ultrafiltrate is collected in the provided centrifuge tube. The device can be spun in a swinging bucket or fixed angle rotor. With their vertical membrane design and deadstop, Amicon® Ultra 15 mL filters deliver the highest recovery with short spin times.
애플리케이션
- Ultrafiltration with 30,000 Dalton molecular weight cutoff Ultracel® membrane.
- Concentration of biological samples containing antigens, antibodies, enzymes, nucleic acids, or microorganisms.
- Purification of macromolecular components found in tissue culture extracts or cell lysates and protein removal prior to HPLS.
- Concentration of dilute or pre-purified proteins from column eluents.
- Desalting, buffer exchange and protein dialysis.
특징 및 장점
- Ultracel® regenerated cellulose membrane with 30 kDa NMWCO delivers retentate recovery of greater than 90%.
- Vertical membrane reduces concentration polarization for ultra-fast spin times (as fast as 10–15 minutes).
- Heat-sealed membrane minimizes downstream extractables.
- 100% integrity tested for reliable performance.
- Convenient sample monitoring with translucent housing and volume gradations.
- Direct pipettor sample access eliminates processing step to recover concentrate.
- High concentration factors of 80–100X.
물리적 형태
법적 정보
적합한 제품을 찾을 수 없으신가요?
당사의 제품 선택기 도구.을(를) 시도해 보세요.
시험 성적서(COA)
제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.
이미 열람한 고객
문서
Filtration methods and membrane filter selection in nanoparticle purification and production.
Filtration methods and membrane filter selection in nanoparticle purification and production.
This page discusses the principles and benefits of using ultrafiltration membranes in protein sample preparation. Possible applications include solvent exchange, protein sample concentration, or sample purification.
프로토콜
Purification protocols for immunoglobulins generally include affinity binding to Protein A or G chromatography media, washing unbound proteins, and eluting with a low pH buffer.
관련 콘텐츠
Purification methods for downstream analysis reduce sample complexity, remove interferences, and concentrate analytes for more accurate results.
Concentrate protein, don’t lose it. Recover protein reliably when you concentrate with Amicon® Ultra filters.
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..