추천 제품
양식
solid
Quality Level
SMILES string
OP(O)(O)=O.CC(C)N(CCC(C(N)=O)(c1ccccc1)c2ccccn2)C(C)C
InChI
1S/C21H29N3O.H3O4P/c1-16(2)24(17(3)4)15-13-21(20(22)25,18-10-6-5-7-11-18)19-12-8-9-14-23-19;1-5(2,3)4/h5-12,14,16-17H,13,15H2,1-4H3,(H2,22,25);(H3,1,2,3,4)
InChI key
CGDDQFMPGMYYQP-UHFFFAOYSA-N
유전자 정보
human ... SCN10A(6336) , SCN11A(11280) , SCN1A(6323) , SCN2A(6326) , SCN3A(6328) , SCN4A(6329) , SCN5A(6331) , SCN7A(6332) , SCN8A(6334) , SCN9A(6335)
유사한 제품을 찾으십니까? 방문 제품 비교 안내
관련 카테고리
애플리케이션
Disopyramide phosphate salt has been used as an internal standard for plasma sample analysis by mass spectrometry. It might be used as a test compound in a teratogenicity study.
생화학적/생리학적 작용
Class IA antiarrhythmic; sodium channel blocker
Disopyramide is found to stabilize the cell membrane by altering the action potential. It might act as an antiarrhythmic agent.
신호어
Warning
유해 및 위험 성명서
예방조치 성명서
Hazard Classifications
Acute Tox. 4 Oral
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
개인 보호 장비
dust mask type N95 (US), Eyeshields, Gloves
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
0
Drugs for Pregnant and Lactating Women, 252-338 (2009)
Anthony A Fossa et al.
The Journal of pharmacology and experimental therapeutics, 302(2), 828-833 (2002-07-20)
QT interval prolongation of the electrocardiogram has been associated with the occurrence of life-threatening fatal ventricular arrhythmias. To understand the relationship between preclinical cardiac conduction assessment to clinical outcome, comparisons of free (unbound)-plasma drug concentrations and their associated effects in
Shunichiro Sumi et al.
Pacing and clinical electrophysiology : PACE, 33(6), e53-e56 (2010-01-12)
The patient was a 57-year-old man with Brugada syndrome, who had been implanted with a implantable cardioverter defibrillator (ICD). The frequency of ventricular fibrillation (VF) started to increase about 4 years after ICD implantation, occurring, at worst, six times in
Annerie M E Moers et al.
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 14(3), 426-430 (2011-09-22)
Patients undergo ablation for focal atrial fibrillation (AF) as a result of failure of anti-arrhythmic drugs. Our basic studies have implicated cholinergic and adrenergic neurotransmitter release as the underlying mechanism for focal AF. Therefore, we tested the efficacy of a
Aziza El Harchi et al.
Journal of molecular and cellular cardiology, 52(1), 185-195 (2011-10-13)
The Class Ia antiarrhythmic drug disopyramide (DISO) causes QT interval prolongation that is potentially dangerous in acquired Long QT Syndrome but beneficial in short QT syndrome, through inhibition of the hERG-encoded channels responsible for rapid delayed rectifier K(+) current (I(Kr)).
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..