추천 제품
Grade
certified reference material
pharmaceutical secondary standard
Quality Level
Agency
traceable to Ph. Eur. Y0001417
traceable to USP 1642879
API family
tadalafil
형태
powder
CofA
current certificate can be downloaded
포장
pkg of 500 mg
기술
HPLC: suitable
gas chromatography (GC): suitable
응용 분야
pharmaceutical (small molecule)
저장 온도
2-30°C
InChI
1S/C22H19N3O4/c1-24-10-19(26)25-16(22(24)27)9-14-13-4-2-3-5-15(13)23-20(14)21(25)12-6-7-17-18(8-12)29-11-28-17/h2-8,16,21,23H,9-11H2,1H3/t16-,21-/m1/s1
InChI key
WOXKDUGGOYFFRN-IIBYNOLFSA-N
유사한 제품을 찾으십니까? 방문 제품 비교 안내
일반 설명
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
Pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.
Tadalafil is a phosphodiesterase type 5 inhibitor that prevents the hydrolysis of cyclic adenosine monophosphate and cyclic guanosine monophosphate.
Pharmaceutical secondary standards for application in quality control provide pharma laboratories and manufacturers with a convenient and cost-effective alternative to the preparation of in-house working standards.
Tadalafil is a phosphodiesterase type 5 inhibitor that prevents the hydrolysis of cyclic adenosine monophosphate and cyclic guanosine monophosphate.
애플리케이션
This pharmaceutical secondary standard can also be used as follows:
- Square-wave voltammetric (SWV) determination of tadalafil in pharmaceutical samples using a boron-doped diamond electrode (BDDE)
- Development of multi-walled and vertically oriented carbon nanotubes (voMWCNT) based electrochemical sensor for the detection of tadalafil in pharmaceutical samples
- Simultaneous determination of sildenafil, tadalafil, and vardenafil in pharmaceutical preparations by a high-temperature gas chromatography/mass spectrometry (HTGC/MS) method
- Development and validation of spectrophotometric methods for the combined analysis of dapoxetine hydrochloride and tadalafil in bulk and pharmaceutical dosage forms
- Spectrophotometric quantification of tamsulosin hydrochloride and tadalafil in their combined pharmaceutical preparation, following International Conference on Harmonization (ICH) guidelines
분석 메모
These secondary standards offer multi-traceability to the USP, EP and BP primary standards, where they are available.
각주
To see an example of a Certificate of Analysis for this material enter LRAB8867 in the Documents slot below. This is an example certificate only and may not be the lot that you receive.
신호어
Warning
유해 및 위험 성명서
Hazard Classifications
Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3
표적 기관
Respiratory system
Storage Class Code
11 - Combustible Solids
WGK
WGK 3
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
이미 열람한 고객
Sensitive square-wave voltammetric determination of tadalafil (Cialis? in pharmaceutical samples using a cathodically pretreated boron-doped diamond electrode
Diamond and Related Materials, 77, 153-158 (2017)
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.