콘텐츠로 건너뛰기
Merck
모든 사진(1)

Key Documents

CWL971S03

Millipore

Milligard® LPB 1.2 µm, Cartridge

pore size 1.2 μm, cartridge nominal length 10 in. (25 cm)

동의어(들):

Milligard Low Protein Binding Cartridge Filter 10 in. Code 7 1.2 μm

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
23151806
eCl@ss:
32031610

material

mixed cellulose esters (MCE) (low protein-binding)
polyester support
polypropylene
silicone seal

Quality Level

무균

non-sterile

멸균 적합성

autoclavable compatible
steam-in-place compatible

제품 라인

Milligard®

특징

hydrophilic

제조업체/상표

Milligard®

파라미터

3.5 bar max. differential pressure (50 psid) at 25 °C
3.5 bar max. inlet pressure (50 psi) at 25 °C

기술

prefiltration: suitable

길이

10 in.

너비

2.9 in.

카트리지 공칭 길이

10 in. (25 cm)

직경

7.1 cm (2.8 in.)

여과 면적

0.8 m2

불순물

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

중량 추출물

≤250 mg/cartridge

기질

Milligard® LPB

공극 크기

1.2 μm nominal pore size
1.2 μm pore size

입력

sample type liquid

카트리지 코드

Code 7

유사한 제품을 찾으십니까? 방문 제품 비교 안내

일반 설명

Device Configuration: Cartridge

특징 및 장점

Format: Single Layer

포장

Double Easy-Open bag

기타 정보

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.
Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer to the installation and wetting sections of OptiScale®-25 user guide and introduction section of the Mixed cellulose esters Tech Brief
  • Storage Statement: Please refer to the Mixed cellulose esters Tech Brief
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

규격

Filter Grade: Low Protein Binding Milligard® Media

제조 메모

Sterilization Method
10 autoclave cycles or SIP @ 121 °C for 30 min
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

분석 메모

Gravimetric Extractables: after a 5 L flush and 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥9 L

법적 정보

MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OptiScale is a registered trademark of Merck KGaA, Darmstadt, Germany

적합한 제품을 찾을 수 없으신가요?  

당사의 제품 선택기 도구.을(를) 시도해 보세요.

픽토그램

Flame

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Flam. Sol. 1

Storage Class Code

4.1B - Flammable solid hazardous materials

WGK

WGK 2


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.