콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

48-623MAG

Millipore

MILLIPLEX® Phospho/Total STAT3 Magnetic Bead 2-Plex Kit - Cell Signaling Multiplex Assay

동의어(들):

2-Plex Phospho/Total Kit, Cell Signaling STAT3 Kit, STAT3 Bead Kit

로그인조직 및 계약 가격 보기


About This Item

UNSPSC 코드:
12161503
NACRES:
NA.47

종 반응성

human, mouse

Quality Level

제조업체/상표

Milliplex®

기술

multiplexing: suitable

검출 방법

fluorometric (Luminex® xMAP®)

저장 온도

2-8°C

일반 설명

STATs (Signal Transducers and Activators of Transcription) are used by receptors for a wide variety of ligands including cytokines, hormones, growth factors and neurotransmitters. The phosphorylation of STAT proteins at conserved tyrosine residues activates SH2-mediated dimerization followed rapidly by nuclear translocation. STAT dimers bind to IRE (interferon response element) and GAS (gamma interferon-activated sequence) DNA elements, resulting in the transcriptional regulation of downstream genes. STAT pathways play important roles in oncogenesis, tumor progression, angiogenesis, cell motility, immune responses and stem cell differentiation.Protein phosphorylation represents the major mechanism used in regulating cellular functions in all eukaryotic cells. Aberrant phosphorylation has been implicated in the onset and development of many diseases including metabolic disorders, inflammatory disease, cancer, etc. Changes in protein phosphorylation can be attributed to both changes in phosphorylation events as well as changes due to total protein levels. In order to distinguish the changes in phosphorylation from changes in protein expression, it is important to normalize the signal from phosphorylation over the signal from total protein. For this need, the MILLIPLEX® MAP 2-plex Phospho/Total STAT3 Kit (Cat. No. 48-623MAG) has been developed for the simultaneous detection of phosphorylated STAT3 (Tyr705) and total STAT3 in a single well using the Luminex system.

특이성

Cross-reactivity between the antibodies and any of the other analytes in this kit is non-detectable or negligible.

애플리케이션

Intracellular Bead-Based Multiplex Assays using the Luminex technology enables the simultaneous relative quantitation of multiple phosphorylation or total pathway proteins in tissue and cell lysate samples. The analytes available for this multiplex kit are: STAT3 (Total), STAT3 (Tyr705).This is an overnight (4°C) incubation assay.This kit must be run using the provided Assay Buffer.This assay requires 25 μL diluted filtered cell lysate per well.The suggested working range of protein concentration for the assay is 1 to 25 μg of total protein/well (25 μL/well at 40 to 1,000 μg/mL).Analytes available:STAT3 (Total)STAT3 (Tyr705)

포장

96-well plate

법적 정보

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

면책조항

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

픽토그램

CorrosionExclamation markEnvironment

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 2 - Eye Dam. 1 - Skin Irrit. 2

Storage Class Code

10 - Combustible liquids


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.