콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

M-106

Supelco

Mycophenolic acid solution

1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C17H20O6
CAS Number:
Molecular Weight:
320.34
UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

certified reference material

양식

liquid

특징

Snap-N-Spike®/Snap-N-Shoot®

포장

ampule of 1 mL

제조업체/상표

Cerilliant®

농도

1.0 mg/mL in acetonitrile

기술

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

응용 분야

clinical testing

형식

single component solution

저장 온도

−70°C

SMILES string

COc1c(C)c2COC(=O)c2c(O)c1C\C=C(/C)CCC(O)=O

InChI

1S/C17H20O6/c1-9(5-7-13(18)19)4-6-11-15(20)14-12(8-23-17(14)21)10(2)16(11)22-3/h4,20H,5-8H2,1-3H3,(H,18,19)/b9-4+

InChI key

HPNSFSBZBAHARI-RUDMXATFSA-N

유전자 정보

일반 설명

Assayed in therapeutic drug monitoring to ensure patients remain within the drug′s therapeutic range, mycophenolic acid is an immunosuppressant drug and the active metabolite of the prodrug mycophenolate mofetil. This analytical standard is suitable for LC-MS/MS applications including therapeutic drug monitoring and other clinical or diagnostic applications.

제조 메모

This product contains an ampule of 1 mL, at a concentration of 1.0 mg/mL in acetonitrile.

법적 정보

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

FlameExclamation mark

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 3 - Eye Irrit. 2 - Flam. Liq. 2

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

35.6 °F - closed cup

Flash Point (°C)

2 °C - closed cup


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Hui Chen et al.
Zhonghua shi yan he lin chuang bing du xue za zhi = Zhonghua shiyan he linchuang bingduxue zazhi = Chinese journal of experimental and clinical virology, 27(1), 35-38 (2013-07-17)
It is well known that cyclosporine A (CsA), a widely used immunosuppressant for clinical organ transplantation, has the ability to inhibit HCV replication. In this study, the effects of several other immunosuppressants, including mycophenolic acid (MPA), rapamycin and FK-506, on
L25. Medical treatment of subglottic stenosis in granulomatosis with polyangiitis (Wegener's).
Paul A Monach
Presse medicale (Paris, France : 1983), 42(4 Pt 2), 575-576 (2013-03-05)
Yutaro Mori et al.
Nihon Jinzo Gakkai shi, 55(2), 177-184 (2013-05-02)
A 26-year-old man diagnosed with nephrotic syndrome was administered steroid monotherapy. Urinary protein excretion was 2-3 g/day despite the therapy. Percutaneous renal biopsy revealed Type I idiopathic membranoproliferative glomerulonephritis (IMPGN). Although intravenous steroid therapy at the dose of 1,000 mg/day
Rene Antonio Cervantes-Castañeda et al.
The British journal of ophthalmology, 97(5), 637-643 (2013-02-26)
To retrospectively report a 12-month follow up for combined therapy with systemic cyclosporine A (CSA) and mycophenolate mofetil (MM) in treatment of patients with birdshot retinochoroidopathy (BSRC). Ninety-eight eyes of patients who received CSA and MM for the treatment of
E Kieslichova et al.
Transplantation proceedings, 45(2), 770-777 (2013-03-19)
The diagnosis of sepsis is difficult in immunocompromised patients owing to their modified response to infection. Our experiment in minipigs was designed to compare responses to sepsis between experimental groups of septic minipigs with and without immunosuppression. Minipigs with identical

문서

LC-MS/MS is a powerful tool that brings numerous benefits to the clinical sample analysis arena. However, due to the complexity of the instrumentation there are some unique challenges that also accompany these benefits. Even following sample extraction and cleanup, matrix effects from the samples can cause interferences or impact ionization efficiency.

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.