콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

F-047

Supelco

Flubromazolam solution

1.0 mg/mL in methanol, certified reference material, ampule of 1 mL, Cerilliant®

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C17H12BrFN4
CAS Number:
Molecular Weight:
371.21
MDL number:
UNSPSC 코드:
41116107
NACRES:
NA.24

Grade

certified reference material

Quality Level

양식

liquid

특징

Snap-N-Spike®/Snap-N-Shoot®

포장

ampule of 1 mL

제조업체/상표

Cerilliant®

농도

1.0 mg/mL in methanol

기술

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

응용 분야

clinical testing

형식

single component solution

저장 온도

−20°C

InChI

1S/C17H12BrFN4/c1-10-21-22-16-9-20-17(12-4-2-3-5-14(12)19)13-8-11(18)6-7-15(13)23(10)16/h2-8H,9H2,1H3

InChI key

VXGSZBZQCBNUIP-UHFFFAOYSA-N

일반 설명

This Certified Spiking Solution® is suitable for testing flubromazolam by HPLC, GC/MS or LC-MS/MS methods in forensic analysis, clinical toxicology, urine drug testing, and cannabis potency or impurity profiling testing applications.

Flubromazolam, a psychoactive compound, is a triazole analog of the designer benzodiazepine, flubromazepam.

애플리케이션

The Certified Reference Material (CRM) in solution can also be used as follows:

  • Residue analysis of nine designer benzodiazepines (DBZDs) in serum samples after their liquid-liquid extraction by non-aqueous capillary electrophoresis coupled with tandem mass spectrometry(MS/MS)
  • Simultaneous determination of 11 designer benzodiazepines from urine samples by liquid chromatography-tandem mass spectrometry (LC-MS/MS)
  • Ultra high-performance liquid chromatography-time-of-flight mass spectrometry (UHPLC-TOF-MS) method based separation and quantification of designer benzodiazepines from serum samples following their liquid-liquid extraction
  • Combination of parallel artificial liquid membrane extraction (PALME) with UHPLC-MS/MS to determine benzodiazepines, designer benzodiazepines, and z-hypnotics from whole blood samples
  • Urine analysis for the testing of 28 designer benzodiazepines reversed phase-LC combined with high-resolution mass spectrometry (HRMS)

특징 및 장점

  • Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
  • Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
  • Flame sealed under argon into ampoules for long-term shelf life
  • Offered in a convenient, DEA-exempt format to improve laboratory efficiency

법적 정보

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

관련 제품

제품 번호
설명
가격

픽토그램

FlameSkull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

표적 기관

Eyes

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

49.5 °F - closed cup

Flash Point (°C)

9.7 °C - closed cup


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

죄송합니다. 지금은 이 제품에 대한 COA이(가) 온라인에서 제공되지 않습니다.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.