콘텐츠로 건너뛰기
Merck
모든 사진(1)

주요 문서

F-017

Supelco

(±)-Flecainide solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

로그인조직 및 계약 가격 보기


About This Item

실험식(Hill 표기법):
C17H20F6N2O3
CAS Number:
Molecular Weight:
414.34
EC Number:
MDL number:
UNSPSC 코드:
41116107
PubChem Substance ID:
NACRES:
NA.24

Grade

certified reference material

Quality Level

양식

liquid

특징

Snap-N-Spike®/Snap-N-Shoot®

포장

ampule of 1 mL

제조업체/상표

Cerilliant®

농도

1.0 mg/mL in methanol

기술

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

응용 분야

clinical testing

형식

single component solution

저장 온도

−20°C

SMILES string

O=C(NCC1CCCCN1)C2=CC(OCC(F)(F)F)=CC=C2OCC(F)(F)F

InChI

1S/C17H20F6N2O3/c18-16(19,20)9-27-12-4-5-14(28-10-17(21,22)23)13(7-12)15(26)25-8-11-3-1-2-6-24-11/h4-5,7,11,24H,1-3,6,8-10H2,(H,25,26)

InChI key

DJBNUMBKLMJRSA-UHFFFAOYSA-N

유전자 정보

human ... SCN5A(6331)

일반 설명

Flecainide, marketed under trade names such as Almarytm, Apocard, Ecrinal®, and Flécaine, is a class Ic antiarrhythmic drug used to prevent and treat a variety of cardiac arrhythmias. This Certified Spiking Solution® is suitable for use as a starting material in the preparation of calibrators, controls, or linearity standards in flecainide therapeutic drug monitoring methods by LC/MS or LC that ensure patients remain within the drug′s narrow therapeutic range.

법적 정보

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Ecrinal is a registered trademark of Laboratoires Asepta Corporation Monaco
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

픽토그램

FlameSkull and crossbonesHealth hazard

신호어

Danger

유해 및 위험 성명서

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

표적 기관

Eyes,Central nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point (°F)

49.5 °F - closed cup

Flash Point (°C)

9.7 °C - closed cup


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 문서 section.

도움이 필요하시면 연락하세요. 고객 지원 부서

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Heather Ellsworth et al.
Pacing and clinical electrophysiology : PACE, 36(3), e87-e89 (2012-08-14)
Flecainide is a Vaughan Williams Class Ic antidysrhythmic associated with PR, QRS, and QTc prolongation on the electrocardiogram and development of life-threatening cardiac toxicity in overdose. The cornerstone of treatment is fluid resuscitation and the administration of magnesium and sodium
[Flecainide intoxication].
Santiago Nogué et al.
Medicina clinica, 140(1), 46-46 (2012-10-03)
Joseph J Lynch et al.
Journal of cardiovascular pharmacology, 61(3), 226-232 (2012-11-29)
This study explored the intrinsic vasorelaxant and inotropic effects of the mixed potassium and sodium channel blocker atrial antiarrhythmic vernakalant and the class IC antiarrhythmic agent flecainide in human isolated subcutaneous resistance artery and in ventricular trabecular muscle preparations. At
Antiarrhythmic drug treatment after cardioversion of atrial fibrillation.
Marcelle D Smit et al.
Lancet (London, England), 380(9852), 1467-1467 (2012-10-30)
ECG diagnosis: flecainide toxicity.
Joel T Levis
The Permanente journal, 16(4), 53-53 (2012-12-20)

문서

For efficient therapeutic drug monitoring, it is important for clinicians to have access to fast and robust analytical methods for accurate assessment of drug efficacy. Industrial trends toward highly specific LC/MS applications over traditional immunoassay have resulted in the need for high-speed chromatographic assays along with simplified sample preparation methods.

The benefit of HILIC over traditional reversed-phase chromatography is two-fold for both sample introduction and analyte detection. First, the high acetonitrile concentration of HILIC mobile phases allows for direct analysis of precipitated plasma samples without the need for additional sample solvent exchange. Second, the high acetonitrile content provides increased analyte response in positive ESI MS detection.

관련 콘텐츠

HILIC mobile phases consist of a high composition of acetonitrile, which facilitates the direct analysis of precipitated plasma samples without the need for additional sample solvent exchange.

Chromatograms

application for HPLCapplication for HPLC

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.