일반 설명
A unit of Hormones in Frozen Human Serum standard reference material (SRM) consists of two vials each of two materials: one from a pool of healthy, premenopausal adult females and one from a pool of healthy adult males. The certified values of the SRM were determined using higher-order reference measurement procedures calibrated with high-purity chemical reference standards in combination with higher-order measurement procedures conducted by the CDC. The uncertainties are expanded uncertainties at the 95 % level of confidence. The certified values of the SRM, apply only to serum thawed to room temperature, 20 °C to 25 °C.
SRM 971a_cert
SRM 971a _SDS
SRM 971a_cert
SRM 971a _SDS
애플리케이션
ThisNIST SRM 971a is intended primarily for use in evaluating the accuracy of procedures for the determination of the steroid hormones cortisol, progesterone, and testosterone, and thyroid hormones total thyroxine (T4), and total 3,3′,5-triiodothyronine (T3) in human serum.
It is also intended for use in validating working or secondary reference materials.
It is also intended for use in validating working or secondary reference materials.
특징 및 장점
- A unit of SRM contains two vials of each material. Each vial approximately contains 2 mL of human serum
- Both materials in the SRM are unfortified
기타 정보
- SRM 971a is intended for research use.
- The serum is shipped frozen (on dry ice) and, upon receipt, should be stored frozen until ready for use.
- Expiration details and storage and use instructions are provided on the NIST certificate
- Notes on biomaterial handling, disposal, and transport documented in MSDS
법적 정보
NIST is a registered trademark of National Institute of Standards and Technology
SRM is a registered trademark of National Institute of Standards and Technology
Storage Class Code
10 - Combustible liquids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
가장 최신 버전 중 하나를 선택하세요:
Annals of laboratory medicine, 43(1), 19-28 (2022-09-01)
Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays at low testosterone concentrations. We developed and validated an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantifying serum total testosterone. We used an ExionLC UPLC (Sciex, Framingham, MA
자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..
고객지원팀으로 연락바랍니다.