콘텐츠로 건너뛰기
Merck
모든 사진(2)

주요 문서

203467

Sigma-Aldrich

Ammonium iodide

99.999% trace metals basis

동의어(들):

Azanium iodide

로그인조직 및 계약 가격 보기


About This Item

Linear Formula:
NH4I
CAS Number:
Molecular Weight:
144.94
EC Number:
MDL number:
UNSPSC 코드:
12352302
eCl@ss:
38050607
PubChem Substance ID:
NACRES:
NA.23
분석:
99.999% trace metals basis
양식:
crystalline
solubility:
ethanol: slightly soluble(lit.)
methanol: slightly soluble(lit.)

vapor pressure

1 mmHg ( 210.9 °C)

Quality Level

분석

99.999% trace metals basis

양식

crystalline

불순물

≤15.0 ppm Trace Metal Analysis

bp

405 °C/1 atm (lit.)

mp

551 °C (lit.)

solubility

ethanol: slightly soluble(lit.)
methanol: slightly soluble(lit.)

SMILES string

N.I

InChI

1S/HI.H3N/h1H;1H3

InChI key

UKFWSNCTAHXBQN-UHFFFAOYSA-N

유사한 제품을 찾으십니까? 방문 제품 비교 안내

애플리케이션

Ammonium iodide can be used as a precursor to prepare polymer electrolytes for dye-sensitized solar cells. It can also be used as a catalyst to synthesize high-purity gallium nitride (GaN) powder.

픽토그램

Health hazard

신호어

Danger

유해 및 위험 성명서

예방조치 성명서

Hazard Classifications

STOT RE 1 Oral

표적 기관

Thyroid

Storage Class Code

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3

Flash Point (°F)

Not applicable

Flash Point (°C)

Not applicable

개인 보호 장비

dust mask type N95 (US), Eyeshields, Gloves


가장 최신 버전 중 하나를 선택하세요:

시험 성적서(COA)

Lot/Batch Number

적합한 버전을 찾을 수 없으신가요?

특정 버전이 필요한 경우 로트 번호나 배치 번호로 특정 인증서를 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

Päivi Pöhö et al.
Journal of chromatography. A, 1598, 175-182 (2019-04-21)
A new heated capillary photoionization (CPI) ion source design was developed to photoionize analytes inside a transfer capillary between a gas chromatograph (GC) and a mass spectrometer (MS). The CPI setup included a wide, oval-shaped vacuum-ultraviolet (VUV) transparent magnesium fluoride
Junseok Lee et al.
Chemosphere, 142, 72-76 (2015-06-29)
A novel approach using wavelength dispersive X-ray fluorescence (WDXRF) spectrometry combined with an activated carbon (AC) disk was developed for the determination of total iodine concentrations in water samples. Dissolved iodine species (i.e., I(-) and IO3(-)) in water samples were
Aline C A Silva et al.
Analytical and bioanalytical chemistry, 407(14), 4091-4099 (2015-04-08)
This work evaluates the application of a thermodynamic model to comprehensive two-dimensional gas chromatography (GC × GC) coupled with time-of-flight mass spectrometry for anabolic agent investigation. Doping control deals with hundreds of drugs that are prohibited in sports. Drug discovery
Ebru Uçaktürk
Journal of analytical methods in chemistry, 2015, 707414-707414 (2015-12-19)
A sensitive and selective gas chromatography-mass spectrometry (GC-MS) method was developed and fully validated for the determination of vildagliptin (VIL) in pharmaceutical formulation. Prior to GC-MS analysis, VIL was efficiently derivatized with MSTFA/NH4I/β-mercaptoethanol at 60°C for 30 min. The obtained O-TMS
M Raro et al.
Journal of mass spectrometry : JMS, 49(6), 509-521 (2014-06-11)
The detection of anabolic androgenic steroids (AAS) is one of the most important topics in doping control analysis. Gas chromatography coupled to (tandem) mass spectrometry (GC-MS(/MS)) with electron ionization and liquid chromatography coupled to tandem mass spectrometry have been traditionally

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..

고객지원팀으로 연락바랍니다.