コンテンツへスキップ
Merck
  • Porous silica particles grafted with an amphiphilic side-chain polymer as a stationary phase in reversed-phase high-performance liquid chromatography.

Porous silica particles grafted with an amphiphilic side-chain polymer as a stationary phase in reversed-phase high-performance liquid chromatography.

Journal of separation science (2015-05-07)
Md Shahruzzaman, Makoto Takafuji, Hirotaka Ihara
要旨

The amphiphilic polymer-grafted silica was newly prepared as a stationary phase in high-performance liquid chromatography. Poly(4-vinylpyridine) with a trimethoxysilyl group at one end was grafted onto porous silica particles and the pyridyl side chains were quaternized with 1-bromooctadecane. The obtained poly(octadecylpyridinium)-grafted silica was characterized by elemental analysis, diffuse reflectance infrared Fourier transform spectroscopy and Brunauer-Emmett-Teller analysis. The degree of quaternization of the pyridyl groups on the obtained stationary phase was estimated to be 70%. The selective retention behaviors of polycyclic aromatic hydrocarbons including some positional isomers were investigated using poly(octadecylpyridinium)-grafted silica as an amphiphilic polymer stationary phase in high-performance liquid chromatography and results were compared with commercially available polymeric octadecylated silica and phenyl-bonded silica columns. The results indicate that the selectivity toward polycyclic aromatic hydrocarbons exhibited by the amphiphilic polymer stationary phase is higher than the corresponding selectivity exhibited by a conventional phenyl-bonded silica column. However, compared with the polymeric octadecylated silica phase, the new stationary phase presents similar retention behavior for polycyclic aromatic hydrocarbons but different retention behavior particularly for positional isomers of disubstituted benzenes as the aggregation structure of amphiphilic polymers on the surface of silica substrate has been altered during mobile phase variation.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
(3-メルカプトプロピル)トリメトキシシラン, 95%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
4-ビニルピリジン, contains 100 ppm hydroquinone as inhibitor, 95%
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
1-ブロモオクタデカン, ≥97.0%
Sigma-Aldrich
アセトニトリル, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
メタノール, suitable for HPLC
Sigma-Aldrich
メタノール, SAJ special grade
Sigma-Aldrich
アセトニトリル, ≥99.8%, suitable for HPLC
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
アセトニトリル 溶液, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
メタノール, NMR reference standard
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 300
Sigma-Aldrich
アセトニトリル, JIS special grade, ≥99.5%
Sigma-Aldrich
アセトニトリル, ≥99.5%, ACS reagent
Sigma-Aldrich
Methanol-12C, 99.95 atom % 12C
Supelco
メタノール 溶液, contains 0.10 % (v/v) formic acid, UHPLC, suitable for mass spectrometry (MS), ≥99.5%
Sigma-Aldrich
2,2'-アゾビス(2-メチルプロピオニトリル), SAJ first grade, ≥98.0%
Sigma-Aldrich
メタノール, JIS 300, ≥99.8%, for residue analysis
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
アセトニトリル, SAJ first grade, ≥99.0%
Sigma-Aldrich
アセトニトリル, for chromatography
Sigma-Aldrich
アセトニトリル, ≥99.8%, for residue analysis, JIS 1000
Sigma-Aldrich
アセトニトリル, for residue analysis, JIS 5000
Sigma-Aldrich
アセトニトリル 溶液, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
アセトニトリル 溶液, contains 0.05 % (v/v) trifluoroacetic acid