コンテンツへスキップ
Merck
  • Analysis of nine food additives in red wine by ion-suppression reversed-phase high-performance liquid chromatography using trifluoroacetic acid and ammonium acetate as ion-suppressors.

Analysis of nine food additives in red wine by ion-suppression reversed-phase high-performance liquid chromatography using trifluoroacetic acid and ammonium acetate as ion-suppressors.

Analytical sciences : the international journal of the Japan Society for Analytical Chemistry (2012-10-13)
Yong-Gang Zhao, Xiao-Hong Chen, Shan-Shan Yao, Sheng-Dong Pan, Xiao-Ping Li, Mi-Cong Jin
要旨

A reversed-phase high-performance liquid chromatography (RP-HPLC) method was developed for the simultaneous determination of nine food additives, i.e., acesulfame, saccharin, caffeine, aspartame, benzoic acid, sorbic acid, stevioside, dehydroacetic acid and neotame in red wine. The effects of ion-suppressors, i.e., trifluoroacetic acid (TFA) and ammonium acetate (AmAc) on retention behavior of nine food additives in RP-HPLC separation were discussed in detail. The relationships between retention factors of solutes and volume percent of ion-suppressors in the mobile-phase systems of acetonitrile-TFA aqueous solution and acetonitrile-TFA-AmAc aqueous solution were quantitatively established, respectively. The results showed that the ion suppressors had not only an ion suppression effect, but also an organic modification effect on the acidic analytes. The baseline separation of nine food additives was completed by a gradient elution with acetonitrile-TFA(0.01%, v/v)-AmAc(2.5 mmol L(-1)) aqueous solution as the mobile phase. The recoveries were between 80.2 - 99.5% for all analytes with RSDs in the range of 1.5 - 8.9%. The linearities were in the range of 0.2 - 100.0 mg L(-1) with determination coefficients (r(2)) higher than 0.9991 for all analytes. The limits of quantification (LOQs) were between 0.53 - 0.99 mg L(-1). The applicability of the proposed method to detect and quantify food additives has been demonstrated in the analysis of 30 real samples.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
トリフルオロ酢酸, ReagentPlus®, 99%
Sigma-Aldrich
トリフルオロ酢酸, suitable for HPLC, ≥99.0%
Sigma-Aldrich
酢酸アンモニウム, ACS reagent, ≥97%
Sigma-Aldrich
トリフルオロ酢酸, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
酢酸アンモニウム, ≥99.99% trace metals basis
Sigma-Aldrich
トリフルオロ酢酸, ≥99%, for protein sequencing
Sigma-Aldrich
酢酸アンモニウム, for molecular biology, ≥98%
Sigma-Aldrich
酢酸アンモニウム 溶液, for molecular biology, 7.5 M
Sigma-Aldrich
酢酸アンモニウム, 99.999% trace metals basis
Supelco
酢酸アンモニウム, LiChropur, eluent additive for LC-MS
Sigma-Aldrich
酢酸アンモニウム, JIS special grade, ≥97.0%
Sigma-Aldrich
酢酸アンモニウム, reagent grade, ≥98%
Supelco
トリフルオロ酢酸, analytical standard
Sigma-Aldrich
酢酸アンモニウム, BioXtra, ≥98%
Sigma-Aldrich
トリフルオロ酢酸, SAJ special grade, ≥99.0%
Sigma-Aldrich
酢酸アンモニウム 溶液, BioUltra, for molecular biology, ~5 M in H2O
Sigma-Aldrich
酢酸アンモニウム, BioUltra, for molecular biology, ≥99.0%
Supelco
ネオテーム, analytical standard
Sigma-Aldrich
酢酸アンモニウム, SAJ first grade, ≥97.0%
Sigma-Aldrich
酢酸アンモニウム 溶液, 50 % (w/v), suitable for iron determination
Sigma-Aldrich
酢酸アンモニウム 溶液, 50 % (w/v), for copper determination