おすすめの製品
包装
pkg of 250 ea
直径
9.5 mm ( 3/8 in.)
適合性
for use with Agilent/HP 5700 series, 5830, 5840
for use with Finnigan 9600
for use with GOW-MAC® all
for use with HNU portable GC
for use with Tracor 550, 560
for use with Varian packed column injectors
類似した製品をお探しですか? 訪問 製品比較ガイド
詳細
Septum is a very important component of syringe injection system. They are usually fabricated from elastomeric, self-sealing materials such as silicone rubber, neoprene or fluoroelastomers. It is suitable to conveniently introducing the sample without causing the system to leak. Improper septa decomposes under the high-temperature conditions of capillary inlets causing baseline disruption and ghost peaks in a chromatogram.
元のThermogreen LB-1セプタムの改良版です。
- ブリードは、広い温度範囲(100°C~350°C)にわたって著しく低く抑えられています。
- すでに調整済みのため、すぐに使用できます。
- ニードルは、穿通が容易で高い破裂耐性を持っています(オートサンプラーに最適です)。
- Supelco社独自のゴムの組成です。
アプリケーション
Thermogreen® LB-2 Septa is suitable for the following applications:
- To minimize extraction onto or loss of analytes off the solid phase microextraction (SPME) fiber from the vial during analysis by GC-MS.
- Thermo-resistant septa is used in GC instrument to avoid carrier gas leaks, extraneous peaks and phthalate contamination.
- Thermo-resistant septa along with thick needle protector is used in GC instruments to avoid damage irreversibly caused by microsyringe.
- It is also used in the influent sampling ports in gas chromatographs.
法的情報
GOW-MAC is a registered trademark of GOW-MAC Instrument Co.
Swagelok is a registered trademark of Swagelok Company
Thermogreen is a registered trademark of Merck KGaA, Darmstadt, Germany
最新バージョンのいずれかを選択してください:
Effect of periods of non-use on biofilter performance.
Journal of the Air & Waste Management Association (1995), 46, 539-546 (1996)
Modern Practice of Gas Chromatography, 471-472 (2004)
Journal of chromatography. A, 999(1-2), 145-153 (2003-07-30)
A simple and efficient liquid-phase microextraction (LPME) technique using a hollow-fibre membrane, in conjunction with gas chromatography-mass spectrometry has been developed for the extraction and analysis of six phthalate esters in water samples. Parameters such as extraction solvent, agitation of
Solid-phase microextraction (SPME) for rapid field sampling and analysis by gas chromatography-mass spectrometry (GC-MS).
TrAC, Trends in Analytical Chemistry, 21, 534-543 (2002)
Chemosphere, 54(7), 849-857 (2003-11-26)
The sonochemical degradation of aqueous solutions containing low concentrations of six phthalate esters at an ultrasonic frequency of 80 kHz has been investigated. Ultrasonic treatment was found capable of removing the four higher molecular mass phthalates (di-n-butyl phthalate, butylbenzyl phthalate
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)