コンテンツへスキップ
Merck
すべての画像(2)

Key Documents

GE11-0034-94

HiTrap® MabSelect SuRe

Cytiva 11-0034-94, pack of 1 × 5 mL

別名:

HiTrap MabSelect SuRe, MabSelect SuRe Column

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
23151816
NACRES:
NA.56

ligand

alkali-stabilized protein A-derived (E. coli)

包装

pack of 1 × 5 mL

メーカー/製品名

Cytiva 11-0034-94

保管条件

(20% Ehtanol)
(20% Ethanol)

パラメーター

<20 mL/min flow rate
42 psi

ベッドサイズ

16 mm × 25 mm

ベッド容積

5 mL

カラム内径

16 mm

マトリックス

highly cross-linked agarose

平均部品サイズ

85 μm (d₅₀v is the median particle size of the cumulative volume distribution)

cleaning

2-13.7

working range

3-12

キャパシティ

≥30 mg binding capacity (humanlgG/ml at 2.4 min residence time)

適合性

suitable for bioprocess medium

保管温度

2-8°C

類似した製品をお探しですか? 訪問 製品比較ガイド

関連するカテゴリー

詳細

Determined at 10% breakthrough by frontal analysis at a mobile phase velocity of 500 cm/h in a column with a bed height of 20 cm.
HiTrap® MabSelect SuRe columns are prepacked with MabSelect SuRe, a BioProcess medium for purification of monoclonal antibodies from large sample volumes. The novel alkali-tolerant recombinant Protein A ligand allow cleaning-in-place (CIP).

HiTrap® MabSelect columns are prepacked with MabSelect a bioprocess medium for capuring of Mabs from large sample volumes.
pH below 3 is sometimes required to elute strongly bound IgG species. However, protein ligands may hydrolyze at very low pH.

特徴および利点

  • Withstands rigorous CIP and sanitization procedures with 0.1 to 0.5 M NaOH.
  • Novel ligand design gives enhanced protease resistance resulting in lower ligand leakage.
  • Oriented coupling of recombinant Protein A to the matrix via an engineered C-terminal cysteine enhances IgG binding capacity.
  • Fewer regulatory concerns due to the total absence of mammalian culture in the ligand production and purification.
  • Prepacked HiTrap® columns for process development, screening of purification conditions, and small-scale purification of Mabs.

アナリシスノート

この製品の分析証明書は、www.cytiva.com.

その他情報

1)The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.
The pressure over the packed bed varies depending on a range of parameters such as the characteristics of the chromatography medium and the column tubing used.

法的情報

Free MabSelect SuRe Ligand
"MabSelect SuRe Ligand Restricted License" and "Cys-rProtein A Ligand Restricted License" are protected by the following patents and equivalent patents and patent applications in other countries: US 6,399,750 and EP 1123389. A free, non-transferable limited license to use this product for internal analytical purposes only accompanies the purchase of the product from a Cytiva company and its licensed distributors. Any other use will require a separate license from a Cytiva company.
HiTrap is a registered trademark of Cytiva
MabSelect is a trademark of Cytiva
MabSelect SuRe is a trademark of Cytiva
SuRe is a trademark of Cytiva

ピクトグラム

Flame

シグナルワード

Warning

危険有害性情報

保管分類コード

3 - Flammable liquids


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

資料

This page shows how to perform sample desalting and buffer exchange for affinity chromatography of antibodies.

プロトコル

This page shows how to separate IgG antibodies by affinity chromatography using MabSelect Sure from GE Healthcare.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)