おすすめの製品
グレード
certified reference material
CofA
current certificate can be downloaded
包装
ampule of 20 mL
メーカー/製品名
RTC QCI-233
濃度
100% in H2O
テクニック
TOC: suitable
アプリケーション
environmental
フォーマット
matrix material
保管温度
2-30°C
詳細
This Certified Reference Material (CRM) is produced and certified in accordance with ISO 17034 and ISO/IEC 17025. All information regarding the use of this CRM can be found on the certificate of analysis.
調製ノート
This PT sample is packaged as a 20 mL concentrate. The solvent for this sample is water. The PT sample has been autoclaved for preservation.
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule PE1388 (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis. Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the "blank" BOD of your seeded dilution water so that the proper seed correction can be made.
To prepare solution, partially fill a 1-L volumetric flask with reagent-grade water. Open ampule PE1388 (be careful to avoid cuts on glass) and transfer 10 mL from the ampule into the flask. Fill the volumetric flask to volume with reagent-grade water and mix well. The sample is now ready for immediate analysis. Analyze the solution to determine BOD or CBOD first. If COD and TOC cannot be determined within two hours after sample preparation, an aliquot should be preserved (pH<2) using 0.2 mL of concentrated sulfuric acid per 100 mL. This aliquot should be stored at 4 degrees Celsius and analyzed as soon as possible within the 28-day maximum holding time.
NOTES: For proper oxygen depletion of BOD and CBOD, the sample should be tested in a dilution series. Use a natural surface water or diluted domestic sewage for seeded dilution water and avoid entrainment of air. For analysis of CBOD, the use of a nitrifying inhibitor is recommended. Be sure to determine the "blank" BOD of your seeded dilution water so that the proper seed correction can be made.
その他情報
検体の値はロットごとに異なります。
アナライト
詳細
5-day BOD 5 - 50 mg/L
Carbonaceous BOD (CBOD) 5 - 50 mg/L
Chemical oxygen demand (COD) 5 - 75 mg/
Total organic carbon (TOC) 1 - 50 mg/L
保管分類コード
12 - Non Combustible Liquids
WGK
nwg
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Jan Code
QC1388-20ML:
Choose from one of the most recent versions: