コンテンツへスキップ
Merck

46264

Sigma-Aldrich

フェロセンカルボン酸

purum, ≥96%

別名:

フェロセニルカルボン酸, フェロセンモノカルボン酸, (カルボキシシクロペンタジエニル)シクロペンタジエニル鉄, カルボキシフェロセン, カルボキシルフェロセン, シクロペンタジエンカルボン酸, フェロセン酸

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
C11H10FeO2
CAS番号:
分子量:
230.04
EC Number:
MDL番号:
UNSPSCコード:
12352300
PubChem Substance ID:
NACRES:
NA.22

グレード

purum

品質水準

アッセイ

≥96%

反応適合性

core: iron
reagent type: catalyst

mp

210 °C (dec.) (lit.)

SMILES記法

[Fe].[CH]1[CH][CH][CH][CH]1.OC(=O)[C]2[CH][CH][CH][CH]2

InChI

1S/C6H5O2.C5H5.Fe/c7-6(8)5-3-1-2-4-5;1-2-4-5-3-1;/h1-4H,(H,7,8);1-5H;

InChI Key

VUJLGCHOGQEAED-UHFFFAOYSA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

Ferrocene carboxylic acid (FCCa) is an organometallic compound comprised of a ferrocene core with a carboxylic acid functional group. It is used as a mediator in electrocatalytic oxidation. Due to its excellent redox properties, it is widely used in electrochemistry, redox probes, and peptide chain modifications. In addition, a direct cross-coupling reaction was explored using ferrocenecarboxylic acid and alkenes.

アプリケーション

Ferrocene carboxylic acid can be used as a:
  • Starting material in the synthesize of ferrocene-guanine conjugates.
  • Redox mediator in electrochemical-chemical-chemical (ECC) redox cycling.

保管分類コード

11 - Combustible Solids

WGK

WGK 3

引火点(°F)

Not applicable

引火点(℃)

Not applicable

個人用保護具 (PPE)

Eyeshields, Gloves, type N95 (US)


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Huilan Su et al.
Biosensors & bioelectronics, 26(11), 4601-4604 (2011-05-31)
A multiple amplification immunoassay was proposed to detect alpha-fetoprotein (AFP), which was based on ferrocenemonocarboxylic-HRP conjugated on Pt nanoparticles as labels for rolling circle amplification (RCA). Firstly, the capture antibody (anti-AFP) was immobilized on glass carbon electrode (GCE) deposited nano-sized
Xuan-Hung Pham et al.
Analytica chimica acta, 671(1-2), 36-40 (2010-06-15)
We developed glucose biosensing electrodes using single-walled carbon nanotube (SWCNT) films on flexible, transparent poly(ethylene terephthalate). The homogeneous SWCNT films were fabricated by a vacuum filtration method, and the averaged resistivity and transparency of the fabricated flexible SWCNT films were
Latif Elci et al.
Talanta, 85(1), 551-555 (2011-06-08)
Solid-phase extraction (SPE) followed by derivatization and gas chromatography-atomic emission detection (GC-AED) was evaluated for the determination of five chlorophenols (CPs) in water samples. The derivatization was based on the esterification of phenolic compounds with ferrocenecarboxylic acid. The determination of
Beatriz Alonso et al.
Chemical communications (Cambridge, England), (16)(16), 1778-1779 (2002-08-29)
A new series of dendrimers with poly(propylene imine) backbones and 4, 8, 16, or 32 peripheral ferrocenyl-urea groups were prepared and characterized; their voltammetric behavior in DMSO solution was very sensitive to the presence of hydrogenphosphate anions at submillimolar concentration
Jean Chrysostome Ndamanisha et al.
Biosensors & bioelectronics, 23(11), 1680-1685 (2008-03-15)
Ordered mesoporous carbon (OMC) functionalized with ferrocenecarboxylic acid (Fc) was used to modify the glassy carbon (GC) electrode. The characterization of OMC-Fc shows that, after anchoring ferrocene on the mesoporous, ordered mesostructure of the material (OMC-Fc) remains intact and Fc

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)