コンテンツへスキップ
Merck

SFUKB

Roche

KAPA SYBR® FAST

suitable for qPCR, 2 ×, Universal

別名:

SYBR, qPCR

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41106300
NACRES:
NA.55

品質水準

使用法

sufficient for 100 reactions
sufficient for 1000 reactions
sufficient for 500 reactions
sufficient for 5000 reactions

シェルフライフ

≤12 mo.

特徴

dNTPs included
hotstart

包装

kit of 1 mL (100 x 20 μL rxn; KK4600)
kit of 10 mL (1000 x 20 μL rxn; KK4602)
kit of 5 mL (500 x 20 μL rxn; KK4601)
kit of 50 mL (5000 x 20 μL rxn; KK4618)

メーカー/製品名

Roche

濃度

2 ×

テクニック

qPCR: suitable

入力

purified DNA

適合性

for use with Agilent Mx3000P
for use with Agilent Mx3005P
for use with Agilent Mx4000
for use with Applied Biosystems® 5700
for use with Applied Biosystems® 7000
for use with Applied Biosystems® 7300
for use with Applied Biosystems® 7500
for use with Applied Biosystems® 7700
for use with Applied Biosystems® 7900HT
for use with Applied Biosystems® ViiA 7
for use with QuantStudio
for use with StepOne
for use with StepOnePlus

検出方法

SYBR® Green

保管温度

−20°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

KAPA SYBR® FAST qPCR Kits contain the first DNA polymerase engineered via directed evolution to be more tolerant of SYBR Green I dye inhibition.

The improved robustness, processivity, and speed of KAPA SYBR FAST qPCR Kits result in consistently high amplification efficiencies enabling more accurate relative quantification for gene expression analysis. KAPA SYBR FAST qPCR Kits, developed to perform optimally in stringent real-time PCR reaction conditions, exhibit dramatic improvements to signal-to-noise ratio (fluorescence), quantification cycle (Cq), linearity, and sensitivity.

アプリケーション

KAPA SYBR® FAST has been used in:
  • Gene expression
  • Gene knockdown validation
  • Microarray validation
  • ChIP analysis
  • Low copy detection
  • Absolute quantification of NGS libraries
  • Quantitative real-time PCR

特徴および利点

Quantitate changes in gene expression more accurately
  • High reaction efficiency between 95 - 105% improves accuracy and reproducibility.
  • Unbiased efficiency across a wide range of GC contents and amplicon lengths.

Detect low copy and difficult targets consistently
  • Improved processivity results in earlier Cq scores.
  • Higher fluorescence detection across varying AT- and GC-rich targets.
  • Novel enzyme is resistant to SYBR® inhibition.

Complete real-time PCR runs in just 40 minutes
  • 55% shorter run times with fast cycling protocol.
  • Maintain high performance when switching from standard to fast protocols.

Quick Notes:
  • This kit contains an engineered enzyme optimized for qPCR using SYBR Green I dye chemistry.
  • The 2X master mix contains a proprietary buffer. Together with the novel enzyme, this improves amplification efficiency of both GC- and AT-rich targets.
  • 20 sec initial denaturation at 95°C is sufficient for enzyme activation. When working with complex templates, an initial denaturation of 3 min is recommended.
  • For 3-step cycling, use 20 sec for primer annealing and 1 sec for extension/data acquisition at 72°C.
  • Do not exceed 25 μL reaction volumes.

品質

All kit components are subjected to stringent functional quality control, are free of detectable contaminating exo and endonuclease activity, and meet strict requirements with respect to DNA contamination.

調製ノート

Always ensure that components have been fully thawed and thoroughly mixed before use. KAPA SYBR® FAST qPCR Master Mix (2X) may not freeze solidly, even when stored at -20°C.

The SYBR Green I dye contained in KAPA SYBR FAST qPCR Master Mix (2X) and ROX/fluorescein dyes (depending on kit configuration) are light sensitive. Exposure to direct light for an extended period of time will result in loss of fluorescent signal intensity.

KAPA SYBR FAST qPCR Master Mix (2X) is stable through 30 freeze-thaw cycles. Ensure that all reagents are stored protected from light at -20°C when not in use. When protected from light, reagents are stable in the dark at 4°C for at least one week and may be stored at this temperature for short-term use, provided that they do not become contaminated with microbes and/or nucleases.

その他情報

For Research Use Only. Not for use in diagnostic procedures.

法的情報

Applied Biosystems is a registered trademark of Applera Corporation or its subsidiaries in the US and/or certain other countries
QuantStudio is a trademark of IROA Technologies LLC
SYBR is a registered trademark of Life Technologies
StepOne is a trademark of Applera Corporation or its subsidiaries in the US and/or certain other countries
StepOnePlus is a trademark of Applera Corporation or its subsidiaries in the US and/or certain other countries

キットの構成要素のみ

製品番号
詳細

  • KAPA SYBR® FAST DNA Polymerase

  • Reaction buffer

  • dNTPs

  • SYBR® Green I dye

  • MgCl2 2.5 mM

  • ROX High Reference Dye (50X)

  • ROX Low Reference Dye (50X)

  • Stabilizers

すべて表示 (8)

ピクトグラム

Health hazard

シグナルワード

Warning

危険有害性情報

危険有害性の分類

STOT SE 2

保管分類コード

12 - Non Combustible Liquids

WGK

WGK 1

引火点(°F)

does not flash

引火点(℃)

does not flash


最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Inhibitory effects of eugenol on RANKL-induced osteoclast formation via attenuation of NF-KB and MAPK pathways.
Deepak V, et al.
Connective tissue research, 56(3), 195-203 (2015)
Regulation of CYP11B1 and CYP11B2 steroidogenic genes by hypoxia-inducible miR-10b in H295R cells.
Nusrin S, et al.
Marine Pollution Bulletin, 85(2), 344-351 (2014)

資料

An overview of directed evolution and the methods for generating proteins with optimized or entirely new functions.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)