コンテンツへスキップ
Merck

SFLCKB

Roche

KAPA SYBR® FAST

suitable for qPCR, 2 ×, for LightCycler®480

別名:

Lightcycler, qPCR

ログイン組織・契約価格を表示する


About This Item

UNSPSCコード:
41106300
NACRES:
NA.55

品質水準

使用法

sufficient for 100 reactions
sufficient for 1000 reactions
sufficient for 500 reactions

シェルフライフ

≤12 mo.

特徴

dNTPs included
hotstart

包装

kit of 1 mL (100 x 20 μL rxn; KK4609)
kit of 10 mL (1000 x 20 μL rxn; KK4611)
kit of 5 mL (500 x 20 μL rxn; KK4610)

メーカー/製品名

Roche

濃度

2 ×

テクニック

qPCR: suitable

入力

purified DNA

適合性

for use with Bio-Rad CFX96
for use with Bio-Rad Chromo4 (Real-Time Detector)
for use with Bio-Rad DNA Engine Opticon
for use with Bio-Rad Opticon 2
for use with Eppendorf® Mastercycler (ep realplex )
for use with Illumina Eco
for use with Roche LightCycler 1.5/2.0
for use with Roche LightCycler 480
for use with Roche LightCycler 96
for use with Roche LightCycler Nano
for use with Rotor-Gene®
for use with Smart Cycler®

検出方法

SYBR® Green

保管温度

−20°C

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

KAPA SYBR® FAST qPCR Kits contain the first DNA polymerase engineered via directed evolution to be more tolerant of SYBR Green I dye inhibition.

The improved robustness, processivity, and speed of KAPA SYBR FAST qPCR Kits result in consistently high amplification efficiencies enabling more accurate relative quantification for gene expression analysis. KAPA SYBR FAST qPCR Kits, developed to perform optimally in stringent real-time PCR reaction conditions, exhibit dramatic improvements to signal-to-noise ratio (fluorescence), quantification cycle (Cq), linearity, and sensitivity.

アプリケーション

KAPA SYBR® FAST for LightCycler®480 has been used for:
  • Gene expression
  • Gene knockdown validation
  • Microarray validation
  • ChIP analysis
  • Low copy detection
  • Absolute quantification of NGS libraries
  • Quantitative real-time PCR (qPCR)

特徴および利点

Quantitate changes in gene expression more accurately
  • High reaction efficiency between 95 - 105% improves accuracy and reproducibility.
  • Unbiased efficiency across a wide range of GC contents and amplicon lengths.

Detect low copy and difficult targets consistently
  • Improved processivity results in earlier Cq scores.
  • Higher fluorescence detection across varying AT- and GC-rich targets.
  • Novel enzyme is resistant to SYBR® inhibition.

Complete real-time PCR runs in just 40 minutes
  • 55% shorter run times with fast cycling protocol.
  • Maintain high performance when switching from standard to fast protocols.

Quick Notes:
  • This kit contains an engineered enzyme optimized for qPCR using SYBR Green I dye chemistry.
  • The 2X master mix contains a proprietary buffer. Together with the novel enzyme, this improves amplification efficiency of both GC- and AT-rich targets.
  • 20 sec initial denaturation at 95°C is sufficient for enzyme activation. When working with complex templates, an initial denaturation of 3 min is recommended.
  • For 3-step cycling, use 20 sec for primer annealing and 1 sec for extension/data acquisition at 72°C.
  • Do not exceed 25 μL reaction volumes.

品質

All kit components are subjected to stringent functional quality control, are free of detectable contaminating exo and endonuclease activity, and meet strict requirements with respect to DNA contamination.

調製ノート

Always ensure that components have been fully thawed and thoroughly mixed before use. KAPA SYBR® FAST qPCR Master Mix (2X) may not freeze solidly, even when stored at -20°C.

The SYBR Green I dye contained in KAPA SYBR FAST qPCR Master Mix (2X) and ROX/fluorescein dyes (depending on kit configuration) are light sensitive. Exposure to direct light for an extended period of time will result in loss of fluorescent signal intensity.

KAPA SYBR FAST qPCR Master Mix (2X) is stable through 30 freeze-thaw cycles. Ensure that all reagents are stored protected from light at -20°C when not in use. When protected from light, reagents are stable in the dark at 4°C for at least one week and may be stored at this temperature for short-term use, provided that they do not become contaminated with microbes and/or nucleases.

その他情報

For Research Use Only. Not for use in diagnostic procedures.

法的情報

Eppendorf is a registered trademark of Eppendorf AG
LightCycler is a registered trademark of Roche
Rotor-Gene is a registered trademark of Qiagen GmbH
SYBR is a registered trademark of Life Technologies
SmartCycler is a registered trademark of Cepheid, Inc.

キットの構成要素のみ

製品番号
詳細

  • KAPA SYBR® FAST DNA Polymerase

  • reaction buffer

  • dNTPs

  • SYBR® Green I dye

  • MgCl2 2.5 mM

ピクトグラム

Health hazard

シグナルワード

Warning

危険有害性情報

危険有害性の分類

STOT SE 2

保管分類コード

12 - Non Combustible Liquids

WGK

WGK 1

引火点(°F)

does not flash

引火点(℃)

does not flash


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Marine compound rhizochalinin shows high in vitro and in vivo efficacy in castration resistant prostate cancer.
Dyshlovoy S A, et al.
Oncotarget, 7(43), 69703-69703 (2016)
Genetic network identifies novel pathways contributing to atherosclerosis susceptibility in the innominate artery.
Albright J, et al.
BMC Medical Genomics, 7, 51-51 (2014)
Microbiota prevents cholesterol loss from the body by regulating host gene expression in mice.
Zhong C Y, et al.
Scientific Reports, 5, 10512-10512 (2015)

資料

An overview of directed evolution and the methods for generating proteins with optimized or entirely new functions.

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)