ミリポアエクスプレス(Millipore Express)®SHRP、オプティキャップ(Opticap)®XLカプセル
sterile, Opticap® XL 10, inlet connection diam. 1.5 in., pore size 0.5/0.1 μm, cartridge nominal length 10 in. (25 cm)
別名:
Opticap Sterile XL 10 Millipore Express SHR with prefilter 0.5/0.1 μm 1-1/2 in. TC/TC
About This Item
おすすめの製品
物質
polyester support
polyethersulfone
polypropylene (gamma-stable)
polypropylene housing
polypropylene vent cap (Gamma stable)
polysulfone
silicone seal
品質水準
法規制遵守
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
無菌性
irradiated
sterile
製品種目
Opticap® XL 10
特徴
hydrophilic
メーカー/製品名
Millipore Express®
パラメーター
≤30.4 mL/min air diffusion at 3.45 bar (50 psig) and 23 °C (in water)
1.0 bar max. differential pressure (15 psid) at 80 °C (Forward)
1.0 bar max. inlet pressure (15 psi) at 80 °C
100 psi max. differential pressure (6.9 bar) (intermittent)
2.1 bar max. differential pressure (30 psid) at 25 °C (Reverse; intermittent)
2.75 bar max. inlet pressure (40 psi) at 60 °C
25 °C max. inlet temp.
5.5 bar max. differential pressure (80 psid) at 25 °C (Forward)
5.5 bar max. inlet pressure (80 psi) at 25 °C
6.9 bar max. differential pressure (100 psid) at 25 °C (Forward; intermittent)
6.9 bar max. inlet pressure (100 psi) at 25 °C (intermittent)
80 psi max. differential pressure (5.5 bar) (continuous)
80 psig max. inlet pressure
テクニック
sterile filtration: suitable
L
33.5 cm (13.2 in.)
カートリッジの長さ(公称)
10 in. (25 cm)
直径
14.5 cm (5.7 in.)
ろ過面積
0.54 m2
入口接続部直径
1.5 in.
入口幅・出口幅
33.5 cm (13.2 in.)
出口接続部直径
1.5 in.
不純物
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)
マトリックス
Millipore Express® SHR (w/Prefilter)
pore size
0.5/0.1 μm pore size
泡立ち点
≥2586 mbar (37.5 psig), nitrogen with 70/30% IPA/water at 23 °C
フィッティング
1/4 in. drain/vent hose barb (with double O-ring Seal)
inlet sanitary flange
outlet sanitary flange
(38 mm (1 1/2 in.) Sanitary Flange Inlet and Outlet)
詳細
包装
その他情報
- Organism Retention: Microorganism
- Mode of Action: Filtration (size exclusion)
- Application: BioProcessing
- Intended Use: Reduction or removal of microorganism/bioburden
- Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
- Storage Statement: Store in dry location
- Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.
調製ノート
123 °C 60 分のオートクレーブ滅菌3回; インライン蒸気滅菌不可
アナリシスノート
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 20 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.