おすすめの製品
物質
glass support
silica gel 60 matrix
品質水準
特徴
binder Organic Polymer
fluorescent indicator
包装
pkg of 25 plates
テクニック
thin layer chromatography (TLC): suitable
層厚
200 μm
プレートL × W
10 cm × 10 cm
粒径
5-6 μm
ポアサイズ
60 Å medium pore diameter
保管温度
2-30°C
詳細
25 Glass plates 10 x 10 cm
関連事項
Replaces: 16464-5; 16464
アナリシスノート
Specific surface area (BET): 460 - 520 m²/g
Pore volume: 0.71 - 0.78 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase:
10 - 20
- Reichstein S, straight phase: 20 - 30
- Methyltestosterone, straight phase: 35 - 47
B) Steroid test, reversed phase
- methyltestosterone, steroid test: 36 - 48
- Reichstein S, steroid test: 46 - 58
- hydrocortisone, steroid test: 56 - 68
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
Pore volume: 0.71 - 0.78 ml/g
d 50 (laser diffraction, size distribution): 5 - 7 µm
Layer thickness: 150 - 200 µm
Deviation of layer thickness per plate: ≤ 35 µm
Chromatographic testings:
A) Steroidtest, straight phase
hRf-values
- hydrocortisone, straight phase:
10 - 20
- Reichstein S, straight phase: 20 - 30
- Methyltestosterone, straight phase: 35 - 47
B) Steroid test, reversed phase
- methyltestosterone, steroid test: 36 - 48
- Reichstein S, steroid test: 46 - 58
- hydrocortisone, steroid test: 56 - 68
Typical value determined on an activated plate (120°C, 15 min)
Eluent a) petroleum benzine 40-60°/acetone (80/20 v/v)
Eluent b) acetone/water (30/70 v/v)
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.