おすすめの製品
特定アナライト
cyanide
品質水準
測定範囲
0.002-0.030 mg/L (CN-)
適合性
for use with MCOLORTEST®
検出方法
colorimetric
保管温度
15-25°C
詳細
Method: colorimetric with color card and comparator block with long test tubes 0.002 - 0.004 - 0.007 - 0.010 - 0.013 - 0.016 - 0.020 - 0.025 - 0.030 mg/l CN MQuant®
The MQuant® Cyanide test (formally MColortest®) measures free cyanide ions e.g. in
Method
Cyanide ions react with a chlorinating agent to form cyanogen chloride, which in turn reacts with 1,3-dimethylbarbituric acid in the presence of pyridine to form a violet dye (König reaction). The cyanide concentration is measured semiquantitatively by visual comparison of the color of the measurement solution with the color fields of a color card.
The unique brilliance of the print and their fine color graduation allow precise analyses, even at the lower end of the concentration range.
Due to the long test tubes a sensitive measurement range can be covered.
Using the refill pack 1.18457 containing all the reagents, the original test kit can be used for a very long time, making it a particularly economical and ecological system.
- Groundwater and surface water
- Drinking water and mineral water
- Waters from aquaculture
- Industrial water
- Wastewater and percolating water
- Electroplating wastewater
- Food after appropriate sample pretreatment
Method
Cyanide ions react with a chlorinating agent to form cyanogen chloride, which in turn reacts with 1,3-dimethylbarbituric acid in the presence of pyridine to form a violet dye (König reaction). The cyanide concentration is measured semiquantitatively by visual comparison of the color of the measurement solution with the color fields of a color card.
The unique brilliance of the print and their fine color graduation allow precise analyses, even at the lower end of the concentration range.
Due to the long test tubes a sensitive measurement range can be covered.
Using the refill pack 1.18457 containing all the reagents, the original test kit can be used for a very long time, making it a particularly economical and ecological system.
法的情報
MCOLORTEST is a registered trademark of Merck KGaA, Darmstadt, Germany
MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
シグナルワード
Danger
危険有害性の分類
Aquatic Chronic 2 - Eye Dam. 1 - Flam. Liq. 3 - Skin Irrit. 2 - STOT RE 2 Inhalation
ターゲットの組織
Respiratory Tract
保管分類コード
3 - Flammable liquids
WGK
WGK 2
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
毒物及び劇物取締法
キットコンポーネントの情報を参照してください
PRTR
キットコンポーネントの情報を参照してください
消防法
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を表示すべき危険物及び有害物
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を通知すべき危険物及び有害物
キットコンポーネントの情報を参照してください
カルタヘナ法
キットコンポーネントの情報を参照してください
Jan Code
キットコンポーネントの情報を参照してください
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)