コンテンツへスキップ
Merck

1.05230

Sigma-Aldrich

Oil red O (C.I. 26125)

for microscopy Certistain®

別名:

Oil red O (C.I. 26125)

ログイン組織・契約価格を表示する


About This Item

CAS番号:
分子量:
408.5
MDL番号:
UNSPSCコード:
41116130
EC Index Number:
215-295-3

組成

Dye, ≥80% spectrophotometric assay

mp

182-186 °C

かさ密度

270 kg/m3

εmax

725-910 at 528-534 nm in chloroform at 0.01 g/L

アプリケーション

diagnostic assay manufacturing
hematology
histology

保管温度

2-30°C

InChI

1S/C26H24N4O/c1-16-9-10-17(2)22(13-16)27-28-23-14-19(4)24(15-18(23)3)29-30-26-21-8-6-5-7-20(21)11-12-25(26)31/h5-15,29H,1-4H3/b28-27?,30-26-

InChI Key

HJAYEODIXUYVIC-LTFAAIOASA-N

類似した製品をお探しですか? 訪問 製品比較ガイド

詳細

The dry dye Oil red O (C.I. 26125) for microscopy Certistain®, is used for the preparation of a staining solution that can be used for the detection of lipids in histological cryo sections. As a Certistain® dye it is chemically quality-certified according to highest standards and strict specifications. Oil red O staining is used for the detection of neutral fat or polyethylene granula in e. g. histological tissues, in joint pathology or in cytological sample material. This Oil red O solution is ready-to-use and results in a brilliant, bright red staining of lipids, while the nuclei are counterstained blue with Hematoxylin solution acc. to Gill II (Cat. no. 105175).
The staining of lipids in histology specimens is a physical process. Oil red O is a lipophilic dye; due to its solubility characteristics it diffuses to the tissue lipids. It is registered as IVD and certified as CE product. For more details, please see instructions for use (IFU). The IFU can be downloaded from this webpage.

アプリケーション

Certistain® dry dye used to detect lipids in cryosections

アナリシスノート

Dye content (spectrophotometrically)≥ 80 %Identity (UV/VIS-Spectrum)passes testAbsorption maximum λ max (chloroform)528 - 534 nmSpec. Absorptivity A 1%/1cm (λmax; 0.01 g/l; chloroform)725 - 910TLC-Testpasses testLoss on drying (110 °C)≤ 8 %Suitability for microscopypasses test

法的情報

CERTISTAIN is a registered trademark of Merck KGaA, Darmstadt, Germany

試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。