Passa al contenuto
Merck
Tutte le immagini(1)

Documenti fondamentali

02553

Sigma-Aldrich

Phosphomolybdic acid solution

ready-to-use spray and plunge reagent, for chromatography

Sinonimo/i:

Molybdophosphoric acid

Autenticatiper visualizzare i prezzi riservati alla tua organizzazione & contrattuali


About This Item

Formula condensata:
H3[P(Mo3O10)4]
Numero CAS:
Peso molecolare:
1825.25
Numero MDL:
Codice UNSPSC:
12171500
ID PubChem:
NACRES:
NA.47

Grado

for chromatography

Livello qualitativo

Stato

liquid

Impiego in reazioni chimiche

reagent type: oxidant

applicazioni

diagnostic assay manufacturing
hematology
histology

Temperatura di conservazione

room temp

Stringa SMILE

O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.OP(O)(O)=O

InChI

1S/12Mo.H3O4P.36O/c;;;;;;;;;;;;1-5(2,3)4;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;/h;;;;;;;;;;;;(H3,1,2,3,4);;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
DHRLEVQXOMLTIM-UHFFFAOYSA-N

Cerchi prodotti simili? Visita Guida al confronto tra prodotti

Descrizione generale

Phosphomolybdic acid solution (PMA), a ready-to-use spray solution is a component of Masson′s trichrome stain. It functions as a mordant, forming a bridge between the substrate and the primary dye.

Applicazioni

Phosphomolybdic acid solution is a ready-to-use spray for the visualization of steroids, alkaloids, antioxidants, and terpenes resolved by thin-layer chromatography (TLC) and high-performance TLC (HPTLC).

Avvertenze

Danger

Indicazioni di pericolo

Classi di pericolo

Eye Dam. 1 - Flam. Liq. 2 - Ox. Liq. 3 - Skin Corr. 1B - STOT SE 3

Organi bersaglio

Central nervous system

Codice della classe di stoccaggio

5.1B - Oxidizing hazardous materials

Classe di pericolosità dell'acqua (WGK)

WGK 3

Punto d’infiammabilità (°F)

53.6 °F - closed cup

Punto d’infiammabilità (°C)

12.0 °C - closed cup

Dispositivi di protezione individuale

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti

I clienti hanno visto anche

Oleg Zui et al.
Talanta, 78(3), 1185-1189 (2009-03-10)
Interaction of luminol with phosphomolybdic, phosphovanadomolybdic and silicomolybdic acids was studied by examination of chemiluminescence spectra, measurement of ESR spectra, investigation of reaction order, and elucidation of inhibition effects. A scheme of the reaction mechanism is proposed.
B Simonovska et al.
Journal of chromatography. A, 903(1-2), 219-225 (2001-01-12)
A high-performance thin-layer chromatographic (HPTLC) method for the determination of the two main potato glycoalkaloids, alpha-chaconine and alpha-solanine, in different parts of the potato plant, is described. Samples were extracted with diluted aqueous acetic acid containing the ion-pairing reagent 1-pentanesulfonic
Juan Feng et al.
Analytical biochemistry, 409(1), 144-149 (2010-10-26)
The classical malachite green (MLG) assay of phosphate, which added MLG after molybdate to the acidified reaction solutions of phosphate, tolerated interference from papaverine, sildenafil, and some similar hydrophobic amines. Resonance Rayleigh scattering signals, the alleviation of interference by poly(vinyl
Andrey V Bulatov et al.
Talanta, 96, 62-67 (2012-07-24)
Simple, rapid and fully automated methods for the manual and automated spectrophotometric determination of epinephrine have been developed by using schemes of stepwise injection (SWIA) and sequential injection analysis (SIA) implemented in the same manifold. The determination is based on
Paweł K Zarzycki et al.
Analytica chimica acta, 688(2), 168-174 (2011-02-22)
The main goal of present paper is to demonstrate the separation and detection capability of micro-TLC technique involving simple one step liquid extraction protocols of complex materials without multi-steps sample pre-purification. In the present studies target components (cyanobacteria pigments, lipids

Il team dei nostri ricercatori vanta grande esperienza in tutte le aree della ricerca quali Life Science, scienza dei materiali, sintesi chimica, cromatografia, discipline analitiche, ecc..

Contatta l'Assistenza Tecnica.