跳转至内容
Merck

1233009

USP

依地酸二钠

United States Pharmacopeia (USP) Reference Standard

别名:

乙二胺四乙酸 二钠盐 二水合物, EDTA 二钠盐, EDTA-Na2, 乙二胺四乙酸Na2, 乙二胺四乙酸盐 二钠盐 二水合物, 二钠乙二胺四乙酸盐 二水合物, 依地酸钙钠

登录查看公司和协议定价


About This Item

经验公式(希尔记法):
C10H14N2Na2O8 · 2H2O
CAS号:
分子量:
372.24
Beilstein:
3900609
分類程式碼代碼:
41116107
NACRES:
NA.24

等級

pharmaceutical primary standard

API 家族

edta

製造商/商標名

USP

mp

248 °C (dec.) (lit.)

應用

pharmaceutical (small molecule)

格式

neat

SMILES 字串

O.O.O.O.[Na+].[Na+].[Na+].[Na+].OC(=O)CN(CCN(CC([O-])=O)CC([O-])=O)CC(O)=O.OC(=O)CN(CCN(CC(O)=O)CC([O-])=O)CC([O-])=O

InChI

1S/C10H16N2O8.2Na.2H2O/c13-7(14)3-11(4-8(15)16)1-2-12(5-9(17)18)6-10(19)20;;;;/h1-6H2,(H,13,14)(H,15,16)(H,17,18)(H,19,20);;;2*1H2/q;2*+1;;/p-2

InChI 密鑰

OVBJJZOQPCKUOR-UHFFFAOYSA-L

正在寻找类似产品? 访问 产品对比指南

一般說明

本品按现行药典规定交付。所有为支持本产品而提供的信息,包括SDS和任何产品信息单均由药典颁发机构制定并发布。如需进一步信息和支持,请访问现行药典网站。

應用

Edetate disodium USP reference standard, intended for use in specified quality tests and assays as specified in the USP compendia. Also, for use with USP monographs such as:
  • Edetate Disodium Injection
  • Edetate Disodium Compounded Ophthalmic Solution
  • Levobunolol Hydrochloride Ophthalmic Solution
  • Budesonide Nasal Spray
二价阳离子的螯合剂。 对需要二价阳离子发挥活性的酶,比如金属蛋白酶具有抑制作用。

分析報告

这些产品仅供测试和化验使用。它们不适用于人类或动物,也不能用于诊断、治疗或治愈任何类型的疾病。

其他說明

可能适用相应的销售限制。

象形圖

Health hazardExclamation mark

訊號詞

Warning

危險聲明

危險分類

Acute Tox. 4 Inhalation - STOT RE 2 Inhalation

標靶器官

Respiratory Tract

儲存類別代碼

11 - Combustible Solids

水污染物質分類(WGK)

WGK 2

閃點(°F)

Not applicable

閃點(°C)

Not applicable


分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

Il Joong Park et al.
Archives of pathology & laboratory medicine, 138(8), 1077-1082 (2014-07-31)
The Samsung LABGEO(HC10) Hematology Analyzer (LABGEO(HC10)) is a recently developed automated hematology analyzer that uses impedance technologies. The analyzer provides 18 parameters including 3-part differential at a maximum rate of 80 samples per hour. To evaluate the performance of the
Pseudothrombocytopenia in a patient receiving romiplostim for immune thrombocytopenic purpura.
Claudio Fozza et al.
Annals of hematology, 93(5), 899-900 (2013-10-02)
Gervasio A Lamas et al.
American heart journal, 168(1), 37-44 (2014-06-24)
Disodium ethylenediaminetetraacetic acid (EDTA) reduced adverse cardiac outcomes in a factorial trial also testing oral vitamins. This report describes the intent-to-treat comparison of the 4 factorial groups overall and in patients with diabetes. This was a double-blind, placebo-controlled, 2 ×
Oivind Midttun et al.
The Journal of nutrition, 144(5), 784-790 (2014-03-22)
Knowledge of stability during sample transportation and changes in biomarker concentrations within person over time are paramount for proper design and interpretation of epidemiologic studies based on a single measurement of biomarker status. Therefore, we investigated stability and intraindividual vs.
S de Vries et al.
Poultry science, 93(8), 2010-2017 (2014-06-17)
Marker methodologies to measure ileal and total tract digestibilities of diets varying in content and degradability of dietary fiber in broiler chickens were evaluated. Chromium sesquioxide (Cr2O3) and cobalt-ethylenediamine tetraacetic acid (Co-EDTA) were used as markers of solid and soluble

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门