产品名称
Ascentis® Express C18, 2.7 μm HPLC 色谱柱, 2.7 μm particle size, L × I.D. 15 cm × 4.6 mm
材料
stainless steel column
agency
suitable for USP L1
產品線
Ascentis®
特點
endcapped
製造商/商標名
Ascentis®
包裝
1 ea of
參數
60 °C temp. range
600 bar max. pressure (9000 psi)
技術
HPLC: suitable
LC/MS: suitable
UHPLC-MS: suitable
UHPLC: suitable
長度 × 內徑
15 cm × 4.6 mm
表面積
135 m2/g
雜質
<5 ppm metals
基質
Fused-Core particle platform
superficially porous particle
基質活性組
C18 (octadecyl) phase
粒徑
2.7 μm
孔徑
90 Å
工作pH值
2-9
應用
food and beverages
分離技術
reversed phase
正在寻找类似产品? 访问 产品对比指南
一般說明
请见 Ascentis Express 主页,了解有关这项新色谱柱技术的更多信息。
應用
法律資訊
應用
相關產品
历史批次信息供参考:
分析证书(COA)
其他客户在看
商品
Compendial methods from the USP (United States Pharmacopeia) are widely used in pharmaceutical drug product and raw materials testing. However, not all methods in the USP use modern technologies. In chromatographic methods, it is not uncommon that older brands of columns are specified. Therefore, the USP methods are under continuous revision to improve existing procedures or to allow the user to obtain better results.
Compendial methods from the USP (United States Pharmacopeia) are widely used in pharmaceutical drug product and raw materials testing. However, not all methods in the USP use modern technologies. In chromatographic methods, it is not uncommon that older brands of columns are specified. Therefore, the USP methods are under continuous revision to improve existing procedures or to allow the user to obtain better results.
Apixaban is sold under the tradename Eliquis and at present no pharmacopeial monographs are available for Axpixaban using either an assay and/or organic impurity profiling method. A newly developed and validated HPLC-UV method using a column with C18 solid core particles is demonstrated.
Ginsenosides Separation in Ginseng. The HPLC method was first optimized using a ginsenoside standard mixture, and was then applied to a sample of American Ginseng root.
实验方案
This paper illustrates the setting up of a Lopinavir assay following European pharmacopoeia guidelines (10.2), and using a shorter column packed with smaller particles. The described assay saves valuable time and improves separation efficiency, which typically translates to better method performance.
This method is particularly useful in research into the role of individual bile acids as signaling molecules; suitable for clinical laboratories to investigate potential mechanisms linked to gut hormone profiles and glycemic control.
HPLC Analysis of Benzene and Deuterated Benzene on Ascentis® Express C18
Chromatograms
application for HPLCapplication for HPLCapplication for HPLCapplication for HPLC展开我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.
联系技术服务部门