跳转至内容
Merck

24022

Supelco

SP®-2340毛细管GC色谱柱

L × I.D. 30 m × 0.25 mm, df 0.20 μm

登录查看公司和协议定价


About This Item

分類程式碼代碼:
41115710
eCl@ss:
32119290

材料

fused silica

agency

meets requirements for USP G5

參數

≤25-250 °C temperature (isothermal or programmed)

β值

313

df

0.20 μm

技術

gas chromatography (GC): suitable

長度 × 內徑

30 m × 0.25 mm

基質活性組

Non-bonded; poly(biscyanopropyl siloxane) phase

柱類型

capillary highly polar

正在寻找类似产品? 访问 产品对比指南

一般說明

Capillary GC column is also known as open tubular column. The carrier gas flows through the central aperture and is unrestricted throughout the length of the column. SP®-2340 is a cyanopropylsiloxane stationary phase, and has high polarity and temperature resistance.
应用:该非键合色谱柱具有同类中最高的极性。与所有通用双氰丙基丙基色谱柱一样,它可在高温和低温下非常有效的分离脂肪酸甲酯(FAME)、二恶英、碳水化合物和芳族化合物的几何异构体。
USP 代码 :该柱符合 USP G5 要求。

  • 非键合
  • 聚(双氰丙基硅氧烷)
温度限制
  • 常温至 250°C(等温或程序升温)

應用

Capillary column coated with SP®-2340 stationary phase may be used in gas chromatographic analysis and separation of cis/trans isomeric fatty acids.

其他說明

We offer a variety of chromatography accessories including analytical syringes

法律資訊

SP is a registered trademark of Sigma-Aldrich Co. LLC

从最新的版本中选择一种:

分析证书(COA)

Lot/Batch Number

没有发现合适的版本?

如果您需要特殊版本,可通过批号或批次号查找具体证书。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库

SP 2340 in the glass capillary chromatography of fatty acid methyl esters.
Heckers HF
Journal of Chromatography A, 136 (2), 311-317 (1977)
T W Lee
Journal - Association of Official Analytical Chemists, 70(4), 702-705 (1987-07-01)
A method has been developed for the quantitative determination of linoleic acid in infant formulas by gas chromatography (GC). A known amount of triheptadecanoin was spiked into the sample. Total lipid was extracted from the product by an ethyl ether-petroleum
C F Poole et al.
Journal of chromatography. A, 912(1), 107-117 (2001-04-20)
The solvation parameter model is used to study the influence of temperature and composition on the selectivity of nine poly(siloxane) and two poly(ethylene glycol) stationary phase chemistries for open-tubular column gas chromatography. A database of system constants for the temperature
Mikael Harju et al.
Journal of chromatography. A, 1019(1-2), 111-126 (2003-12-03)
Comprehensive two-dimensional gas chromatography (GC x GC) of the 209 polychlorinated biphenyls (CBs) was carried out using a longitudinally modulated cryogenic system (LMCS) and liquid carbon dioxide as cryogen. The effluent from a non-polar column was modulated and further separated
Waruna Kiridena et al.
Journal of separation science, 30(5), 740-745 (2007-04-28)
The solvation parameter model is used to characterize the separation properties of the polar stationary phases EC-Wax and PAG with a poly(ethylene oxide) backbone (substituted with propylene oxide in the case of PAG) and the cyanopropyl-substituted polysilphenylene-siloxane stationary phase BPX90

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门